Frymaster SCFHD operation manual Gas Conversion Procedures, CE only Altitudes of 2000 feet or less

Page 20

HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS

CHAPTER 3: INSTALLATION

3.5Gas Specifications

CE ONLY (Altitudes of 2000 feet or less)

MODEL

INPUT

GAS

ORIFICE

ORIFICE

QTY

EQUIPMENT

PRESSURE

(kW)

TYPE

(MM)

PART NO.

 

 

MBAR

INCH W.C.

 

 

 

 

 

 

D20G

15,0

G20

2,40

810-2060

2

10,0

4,0

G25

2,40

810-2060

2

15,0

6,0

 

 

G31

1,51

810-2059

2

27,0

10,8

 

 

G20

2,40

810-2060

4

10,0

4,0

D50G

30,0

G25

2,40

810-2060

4

15,0

6,0

 

 

G31

1,51

810-2059

4

27,0

10,8

 

 

G20

2,40

810-2060

5

10,0

4,0

D60G

37,5

G25

2,40

810-2060

5

15,0

6,0

 

 

G31

1,51

810-2059

5

27,0

10,8

 

 

G20

2,40

810-2060

5

10,0

4,0

D80G

37,5

G25

2,40

810-2060

5

15,0

6,0

 

 

G31

1,51

810-2059

5

27,0

10,8

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.

(Pilot Flame Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-volume is achieved.)

3.6 Gas Conversion Procedures

DANGER

This appliance was configured at the factory for a specific type of gas. Converting from one gas type to another requires the installation of specific gas-conversion components.

Switching to a different type of gas without installing the proper conversion components may result in fire. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be

performed by qualified, licensed, and authorized installation or service personnel, as

defined in Section 1.6 of this manual.

Contact factory with the following information when performing conversions:

Fryer Serial Number

Gas Type

Fryer Model Number

Operating Altitude

Conversions can only be executed by qualified, factory-authorized personnel.

Pilot pressure adjustment

Pressure flow adjustment

(remove cover screw to

(remove cover screw to

access)

access)

 

Regulator Vent

Pilot gas supply

ON/OFF

connection.

 

Gas-Cock Knob

Typical non-CE gas valve for electronic-ignition equipped fryers.

3-7

Image 20
Contents Hour Service Hotline HD Models Series Gas FryersCanada Page Table of Contents High Efficiency Decathlon HD Series Gas FryersTable of Contents Ordering Parts Applicability and ValidityAfter Purchase Computer Information Service InformationSafety Information Service Personnel Qualified and/or Authorized Operating PersonnelReceiving and Unpacking Equipment GeneralProduct Description Principles of OperationPre-installation Rating PlateInstallation Standards Air Supply and VentilationEquipment Installed at High Altitudes Installing the Fryer Leveling the Fryer Fryers equipped with legs onlyInstalling Casters and Legs Rear Only Front OnlyGas Connections National Code RequirementsGas Supply Type and Pressure Gas Connections Gas Specifications NON-CE Altitudes of 2000 feet or lessGas Conversion Procedures CE only Altitudes of 2000 feet or lessElectrical Connections Initial Start-up Pilot Lighting Procedures, Standing Pilot Only Boil-Out Procedure Boil-Out Procedure Final Preparation Final Preparation Operating Instructions Electronic Thermostat Controller When in use Electronic Thermostat Controller/ComputerElectronic Thermostat Controller/Computer High Efficiency Decathlon HD Series GAS Fryers Filtration Filter Preparation Filter Unit TypesFilter Leaf Assembling the Filter Crumb screen properly placed Handle Applying filter powder to filter-leaf Installing the Filter Filtering Tools Operating the Filter Pan Preparation and OperationMove the red drain valve handle into the open position Filter Operation SUFF/UFF Filtration Systems Installation and Operation Do not Allow Crumbs to Accumulate in Tray Optional Filter Hose and Wand Operation Complete Filtering Hose and Wand OperationDaily WeeklyStainless Steel Care See filtration manual for filtration maintenance proceduresPeriodic/ Annual Pilot Burner Malfunction Main Burner Malfunctions Electronic Thermostat Controller Calibration Service Hotline