Frymaster FGP55 operation manual National Code Requirements

Page 12

2.3.1 General Installation Requirements (cont.)

One of the most important considerations of efficient operation is ventilation. Make sure the equipment is installed so that products of combustion are removed efficiently, and that the kitchen ventilation system does not produce drafts that interfere with proper burner operation.

The equipment flue opening must not be placed close to the intake of the exhaust fan, and the flue must never be extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the equipment, causing longer recovery times. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the front, sides, and rear of the unit must be kept clear and unobstructed.

This equipment must be installed in an area with an adequate air supply and adequate ventilation. For U.S installations, information on construction and installation of ventilating hoods can be found in NFPA Standard 96. This document can be ordered from the National Fire Protection Association, Battery March Park, Quincy, MA 02269. For installations in countries other than the U.S., the appropriate regulating authority should be contacted for information related to hood construction and installation.

DANGER

Do not attach an apron drain to a single rethermalizer. The rethermalizer may

become unstable, tip over, and cause injury to personnel.

NATIONAL CODE REQUIREMENTS

This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration.

This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped “NAT” only to natural gas and that stamped “PRO” only to LP (Propane) gas.

Installation shall be made with a gas connector that complies with national and local codes. Quick disconnect devices, if used, shall likewise comply with national and local codes.

ELECTRICAL GROUNDING REQUIREMENTS

All electrically operated appliances must be grounded in accordance with all applicable national and local codes. A wiring diagram is located on the inside of the door. In the United States and Canada, the electrical supply must be 120VAC, 60 Hz. In other countries, refer to the rating plate on the inside of the door for proper voltages.

2-3

Image 12
Contents 8195845 Page Canada Table of Contents FGP55 Component Identification FGP55 Rethermalizer Sequence of Operation Safety Information FGP55 Series RethermalizerShipping Damage Claim Procedure Maintenance/Repair InformationComputer Information Retain and Store this Manual in a Safe Place for Future USE FGP55 Series Rethermalizers Installation GeneralService Personnel Installation InstructionsNational Code Requirements Caster/Leg Installation Pre-Connection PreparationsIncoming Gas Pressures Check for GAS Leaks Converting to Another Gas Type Boil-Out InstructionsOnly Introduction Lighting InstructionsDaily Checks and Services Inspect Rethermalizer and Accessories for DamageQuarterly Checks and Services Check Computer Magic III.5 Setpoint AccuracyComputer Operation DescriptionProgramming the FGP55 CM-III.5 Computer Programming the FGP55 CM-III.5 Computer Operating the FGP55 Rethermalizer FGP55 Temperature Display Options FGP55 Computer Display Messages10 FGP55 Boil or Simmer Mode Options 11 FGP55 Clock Display OptionsThis page Intentionally Left Blank Service Hotline