Frymaster FGP55 Quarterly Checks and Services, Check Computer Magic III.5 Setpoint Accuracy

Page 20

3.3Daily Checks and Services (cont.)

Clean the temperature probe and high-limit, located on the burner tube in the cook vessel. Using a Scotchbrite™ or similar mildly abrasive pad and a solution of detergent and water, clean the inside of the cookpot.

Clean all food-contact surfaces with a proper dilution of a sanitizing detergent.

Rinse the cookpot thoroughly with clean water at least twice.

3.4Quarterly Checks and Services

Check Computer Magic III.5 Setpoint Accuracy

1.Fill the cookpot with water. Press the computer power switch, and then press any of the product buttons. Insert a good-grade thermometer or pyrometer probe into the cookpot, with the end touching the temperature probe.

When the computer display shows a series of four dashes (

), press the

switch once to

display the temperature of the water as sensed by the temperature probe. Press the

switch twice

to display the setpoint. The displayed water temperature should be within ±10°F (5°C) of the setpoint. The temperature shown on the thermometer or pyrometer should be within ± 5ºF (2ºC) of the displayed water temperature. If either set of readings is outside its range, contact a Factory Authorized Service Center for assistance.

3-3

Image 20
Contents 8195845 Page Canada Table of Contents FGP55 Component Identification FGP55 Rethermalizer Sequence of Operation Safety Information FGP55 Series RethermalizerComputer Information Shipping Damage Claim ProcedureMaintenance/Repair Information Retain and Store this Manual in a Safe Place for Future USE FGP55 Series Rethermalizers Installation GeneralService Personnel Installation InstructionsNational Code Requirements Caster/Leg Installation Pre-Connection PreparationsIncoming Gas Pressures Check for GAS Leaks Converting to Another Gas Type Boil-Out Instructions Only Introduction Lighting InstructionsDaily Checks and Services Inspect Rethermalizer and Accessories for DamageQuarterly Checks and Services Check Computer Magic III.5 Setpoint AccuracyComputer Operation DescriptionProgramming the FGP55 CM-III.5 Computer Programming the FGP55 CM-III.5 Computer Operating the FGP55 Rethermalizer FGP55 Temperature Display Options FGP55 Computer Display Messages10 FGP55 Boil or Simmer Mode Options 11 FGP55 Clock Display OptionsThis page Intentionally Left Blank Service Hotline