Frymaster operation manual 10 FGP55 Boil or Simmer Mode Options, 11 FGP55 Clock Display Options

Page 26

3.9 FGP55 Computer Display Messages (cont.)

e(four dashes) – Indicates that the water temperature is within the proper rethermalizing range (i.e., within ±11°F of setpoint).

e – Indicates that there is a heating problem. Call your local Factory Authorized Service Center or the 24-Hour Hotline (1-800-551-8633).

e – Indicates that the rethermalizer has detected a problem in the temperature control circuits. Call your local Factory Authorized Service Center or the 24-Hour Hotline (1-800- 551-8633).

3.10FGP55 Boil or Simmer Mode Options

In the Simmer Mode, the vessel temperature is maintained at the setpoint programmed by the operator. In the Boil Mode, the vessel temperature is raised to 212°F (100°C).

Select the Simmer Mode by pressing the (R) button. If the temperature of the vessel is above the setpoint, °- will be displayed. If the temperature of the vessel is below the setpoint, °- will

be displayed. If the temperature is within 11°F (6°C) of the setpoint, (four dashes) will be displayed.

The Boil Mode is selected by pressing the (L) button. The computer will display and the temperature of the vessel will be raised to 212°F (100°C).

See Section 2.6 for detailed boil-out instructions.

3.11 FGP55 Clock Display Options

The computer can be programmed to display rethermalizing time in minutes and seconds, or in hours and minutes, depending on the product being rethermalized.

To toggle between display options, press the switch, enter 1 6 5 3, then press the . To determine which display is active, initiate a rethermalizing cycle by pressing a product button. If the display is set to minutes and seconds, the time will immediately begin to count down. If it does not, the display is set to hours and minutes.

3–9

Image 26
Contents 8195845 Page Canada Table of Contents FGP55 Component Identification FGP55 Rethermalizer Sequence of Operation Safety Information FGP55 Series RethermalizerComputer Information Shipping Damage Claim ProcedureMaintenance/Repair Information Retain and Store this Manual in a Safe Place for Future USE FGP55 Series Rethermalizers Installation GeneralService Personnel Installation InstructionsNational Code Requirements Caster/Leg Installation Pre-Connection PreparationsIncoming Gas Pressures Check for GAS Leaks Converting to Another Gas Type Boil-Out InstructionsOnly Introduction Lighting InstructionsDaily Checks and Services Inspect Rethermalizer and Accessories for DamageQuarterly Checks and Services Check Computer Magic III.5 Setpoint AccuracyComputer Operation DescriptionProgramming the FGP55 CM-III.5 Computer Programming the FGP55 CM-III.5 Computer Operating the FGP55 Rethermalizer FGP55 Temperature Display Options FGP55 Computer Display Messages10 FGP55 Boil or Simmer Mode Options 11 FGP55 Clock Display OptionsThis page Intentionally Left Blank Service Hotline