Frymaster FGP55 operation manual Introduction, Lighting Instructions

Page 18

FGP55 SERIES RETHERMALIZERS

CHAPTER 3: OPERATING INSTRUCTIONS

3.1 Introduction

The FGP55 rethermalizer is offered with a standing pilot with Piezo ignitor or electronic ignition. The unit is equipped with a low-level float switch, which allows ignition of the burners only after the proper water level is reached. An auto-refill float switch maintains the normal water level. A water by-pass switch, located below the control panel (see Page iv), can be used to raise the water level for boil-out or in the case of a failure in the auto-refill mode.

Cold food should not be added to the cookpot, if the rethermalizer is in the hot-food holding mode.

3.2 Lighting Instructions

CAUTION

Vessel MUST be filled with water before lighting.

Follow these instructions for units equipped with a standing pilot:

1.Press the switch to turn the computer ON. If the vessel is not filled to the proper level

with water, the AutoFill feature will add water to the proper level.

2.Turn the gas valve knob (open the door to gain access) to the OFF position. Wait 5 minutes before proceeding.

3.Turn the gas valve knob to the PILOT position.

4.Push and hold the knob in. Simultaneously, press the Piezo ignitor button repeatedly until the pilot lights. Continue to depress the gas valve pilot knob approximately 60 seconds. Release the knob.

5.The pilot flame should remain lit. If the pilot goes out, wait at least 5 minutes, then follow Step 4 to re-light the pilot.

6.Turn the gas valve knob to the ON position.

7.An illuminated dot between digits 1 and 2 in either LED display indicates that the burners are lit.

8.If the burners fail to light, press the switch to turn the computer OFF and wait 60 seconds. Repeat the preceding steps.

NO

 

 

OFF

 

 

 

 

 

 

P

 

 

 

I

 

 

L

 

O

 

 

T

 

 

O

F

F

 

 

 

P

I

L

TO

NO

 

OT

 

L

 

I

 

 

P

 

 

FFO

 

ON

 

 

3-1

Image 18
Contents 8195845 Page Canada Table of Contents FGP55 Component Identification FGP55 Rethermalizer Sequence of Operation Safety Information FGP55 Series RethermalizerShipping Damage Claim Procedure Maintenance/Repair InformationComputer Information Retain and Store this Manual in a Safe Place for Future USE FGP55 Series Rethermalizers Installation GeneralService Personnel Installation InstructionsNational Code Requirements Caster/Leg Installation Pre-Connection PreparationsIncoming Gas Pressures Check for GAS Leaks Converting to Another Gas Type Boil-Out InstructionsOnly Introduction Lighting InstructionsDaily Checks and Services Inspect Rethermalizer and Accessories for DamageQuarterly Checks and Services Check Computer Magic III.5 Setpoint AccuracyComputer Operation DescriptionProgramming the FGP55 CM-III.5 Computer Programming the FGP55 CM-III.5 Computer Operating the FGP55 Rethermalizer FGP55 Temperature Display Options FGP55 Computer Display Messages10 FGP55 Boil or Simmer Mode Options 11 FGP55 Clock Display OptionsThis page Intentionally Left Blank Service Hotline