PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model
Model
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine, Taste and Odor, Particulate Class lll*; and against ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Benzene, and
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Aesthetic Effects | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
|
|
|
|
|
|
|
|
Chlorine Taste/Odor | ≥50% | 1.9 mg/L | 2.0 mg/L ± 10% | 0.07 mg/L | 0.06 mg/L | >75.0% | >75.0% |
Particulate Class III* | ≥85% | 49,333/mL | At least 10,000 particles/mL | 640 mg/L** | 312 mg/L | 98.7% | 99% |
|
|
|
|
|
|
|
|
Contaminant | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Reduction | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.01mg/L | 0.14 mg/L*** | 0.15 mg/L ± 10% | 0.0014 mg/L | 0.0011 mg/L | 99.0% | 99.21% |
Lead: @ pH 8.5 | 0.01mg/L | 0.15 mg/L*** | 0.15 mg/L ± 10% | 0.0069 mg/L | 0.0042 mg/L | 95.4% | 97.08% |
|
|
|
|
|
|
|
|
Mercury: @ pH 6.5 | 0.002 mg/L | 0.0059 mg/L | 0.006 mg/L ± 10% | 0.0009 mg/L | 0.0004 mg/L | 84.74% | 92.47% |
Mercury: @ pH 8.5 | 0.002 mg/L | 0.0054 mg/L | 0.006 mg/L ± 10% | 0.0007 mg/L | 0.00043 mg/L | 87.03% | 91.93% |
|
|
|
|
|
|
|
|
Benzene | 0.0050 mg/L | 0.0157 mg/L | 0.015 ± 10% | 0.002 mg/L | 0.00083 mg/L | 87.26% | 94.71% |
|
|
|
|
|
|
|
|
0.075 mg/L | 0.210 mg/L | 0.225 ± 10% | 0.0005 mg/L | 0.0005 mg/L | 99.76% | 99.76% | |
|
|
|
|
|
|
|
|
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Model
Model
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the front cover or “Accessories” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8° C) |
Service Flow Rate | 0.5 GPM (1.89 L/min.) @ 60 psi. |
|
|
*Class III particle size: >5 to <15 um
**Test requirement is at least 10,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International.