Troubleshooting Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.
Diagnostic Code Checking
Code
Description
When Checked
Detection
1c1c | Shorted key | Always | 1 minute |
1c2c | Keyboard tail disconnected | Always | 1 minute |
1c31 | Cancel key circuit problem | Always | 20 seconds |
1c32 | Cancel key circuit problem | Always | 20 seconds |
1c6c | EEPROM error | When accessing EEPROM | 3 tries |
1c7c | Control not calibrated | Always | 3 tries |
1c8c | Cooking program error | Cook or clean programmed | 3 tries |
1d11 | Runaway temp (650°F), door unlocked | Latch unlocked | 1 minute |
1d12 | Runaway temp (650°F), door unlocked | Latch unlocked | 1 minute |
1d21 | Runaway temp (950°F), door locked | Latch locked | 1 minute |
1d22 | Runaway temp (950°F), door locked | Latch locked | 1 minute |
3d11 | Sensor open | Cook or clean active | 20 seconds |
3d12 | Sensor open | Cook or clean active | 20 seconds |
3d21 | Sensor shorted | Cook or clean active | 20 seconds |
3d22 | Sensor shorted | Cook or clean active | 20 seconds |
4d11 | Door switch position failure | Clean or keyboard Lockout active | 1 minute |
4d12 | Door switch position failure | Clean or keyboard Lockout active | 1 minute |
4d21 | No reverse airflow fan rotation (no/low RPM) | Clean or Cook programmed | 1 minute |
4d31 | Reverse airflow fan state (on when should be off) | Suppose to be OFF | 1 minute |
4d51 | Door switch circuit failure | Convect, Clean or Keyboard Lockout programmed | 1 minute |
4d52 | Door switch circuit failure | Convect, Clean or Keyboard Lockout programmed | 1 minute |
9d11 | Latch will not lock | Latch should be locked | See Note 6 |
9d12 | Latch will not lock | Latch should be locked | See Note 6 |
9d21 | Latch will not unlock | Latch should be unlocked | See Note 6 |
9d22 | Latch will not unlock | Latch should be unlocked | See Note 6 |
9d31 | Latch state unknown, both locked and unlocked | Latch should be locked or when lock attempted | See Note 6 |
9d32 | Latch state unknown, both locked and unlocked | Latch should be locked or when lock attempted | See Note 6 |
Diagnostic Code Handling
Code | Measurable | What is Displayed | Action Taken By Control | |
|
|
| Disables audible for affected key depression | |
1c1c | Keypress | Nothing | Disables all outputs 1, 2 | |
|
|
| Disables lights and timers | |
|
|
| Disables audible for key depression | |
1c2c | Keyboard loop improper value | Nothing | Disables all outputs 1 | |
|
|
| Disables lights and timers | |
1c31 | Cancel key improper value | BAKE flashes 3 | Disables all outputs for cavity 1 | |
1c32 | Cancel key improper value | BAKE flashes 3 | Disables all outputs for cavity 1 | |
1c6c | No response from EEPROM | Nothing | Disables all outputs 1 | |
1c7c | Calibration value out of range | “CAL” in the time digits | Completely disables oven 4 | |
1c8c | CRC invalid | Nothing | Cancels active cook function | |
1d11 | Sensor resistance > 2237 Ω | BAKE flashes 3 | Disables all cook function for cavity | |
1d12 | Sensor resistance > 2237 Ω | BAKE flashes 3 | Disables all cook function for cavity | |
1d21 | Sensor resistance > 2787 Ω | BAKE flashes 3 | Disables all cook function for cavity | |
1d22 | Sensor resistance > 2787 Ω | BAKE flashes 3 | Disables all cook function for cavity | |
3d11 | Sensor resistance > Infinite Ω | BAKE flashes 3 | Disables all cook function for cavity | |
3d12 | Sensor resistance > Infinite Ω | BAKE flashes 3 | Disables all cook function for cavity | |
3d21 | Sensor resistance > 0 Ω | BAKE flashes 3 | Disables all cook function for cavity | |
3d22 | Sensor resistance > 0 Ω | BAKE flashes 3 | Disables all cook function for cavity | |
4d11 | Door switch not closed when door is locked | Nothing | Disables Clean and Lockout functions 5 | |
4d12 | Door switch not closed when door is locked | Nothing | Disables Clean and Lockout functions 5 | |
4d21 | No reverse airflow fan rotation (no/low RPM) | Nothing | Disables all cook function for cavity | |
4d31 | Reverse airflow fan state (on when should be off) | Nothing | No action | |
4d51 | Door switch not open or closed | Nothing | Disables Convect, Clean, and Lockout functions 4, 5 | |
Turn off light and disable light from door switch | ||||
|
|
| ||
4d52 | Door switch not open or closed | Nothing | Disables Convect, Clean, and Lockout functions 4, 5 | |
Turn off light and disable light from door switch | ||||
|
|
| ||
9d11 | Lock switch not closed | LOCK flashes 3 | Disables Clean and Lockout functions 4 | |
9d12 | Lock switch not closed | LOCK flashes 3 | Disables Clean and Lockout functions 4 | |
9d21 | Unlock switch not closed | LOCK flashes 3 | Disables Clean and Lockout functions 4 | |
9d22 | Unlock switch not closed | LOCK flashes 3 | Disables Clean and Lockout functions 4 | |
9d31 | Latch both locked and unlocked | LOCK flashes 3 | Disables Clean and Lockout functions 4 | |
9d32 | Latch both locked and unlocked | LOCK flashes 3 | Disables Clean and Lockout functions 4 |