Testing Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.
Illustration | Component | Test Procedure | Results |
| Triple thermal valve | Disconnect wiring to valve. |
|
|
| Measure resistance on upper and |
|
|
| lower bake circuit | Continuity, If not replace. |
|
| Measure resistance on broil circuit | Continuity, If not replace. |
|
|
| ! WARNING |
|
|
| Do not attempt to open valve with |
| |
|
|
| 120 VAC. |
|
|
|
|
|
|
Pressure regulator | Verify gas pressure (W.C.P.). | 5" Natural |
|
|
| If on LP service verify proper gas | 10" LP/propane | ||
|
|
|
| |
| supply conversion. |
|
|
|
|
|
|
|
|
Shut off valve | Check to verify gas supply is turned | Gas ON .... | slot at 9 o’clock position | |
| on. | Gas OFF... | slot at 12 o’clock position | |
| Located on surface valve manifold |
|
|
|
| near maintop upsweep. |
|
|
|
|
|
|
|
|
Convection Assembly | Measure voltage | 120 VAC. |
|
|
Convection Element | Remove wires, check resistance | Approximately 28 to 33 Ω. | ||
Convection Motor | Check motor windings to ground | No continuity. | ||
|
| Approx. 900 RPM. | ||
Model MGR6875AD* |
|
|
|
|
Power cord | Verify resistance of wires to | Continuity |
|
|
| terminals. |
|
|
|
18 | 16023415 | ©2004 Maytag Services |