Briggs & Stratton 01897-0 owner manual Before Initial START-UP, Fuel System Selection, Engine Oil

Page 17

Briggs & Stratton Power Products Standby Generator

Installation, Start-Up and Owner’s Manual

BEFORE INITIAL START-UP

Engine Oil

This engine is shipped from the factory filled with the recommended oil. Before starting the engine, check oil level and ensure that engine is serviced as described in the engine owner’s manual.

CAUTION

Any attempt to crank or start the engine before it has been properly serviced with the recommended oil will result in equipment failure.

Refer to engine manual for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

Oil Considerations

Your Standby Generator is equipped with an engine that has been pre-run at the factory and does not require the traditional “break-in” procedure.

The generator is filled with synthetic oil (API SJ/CF 5W- 30W).This allows for generator operation in the widest range of temperature and climate conditions.

NOTE: The use of synthetic oil DOES NOT alter the required oil change intervals described in the engine owner’s manual.

7.Ensure hardware on both positive and negative battery terminals is secure.

8.Reinstall 15 Amp fuse in control panel.

CAUTION

Installing the 15A fuse could cause the engine to start.

DO NOT install the 15 Amp fuse until all plumbing and wiring has been completed and inspected.

9.Reinstall service disconnect in disconnect box.

10.Set generator's “AUTO/OFF/MANUAL” switch to AUTO.

11.Reset exercise timer following instructions “Setting Exercise Timer” on page 19.

NOTE: With the battery installed and utility power available to the Transfer Switch, the battery receives a trickle charge whenever the engine is not running.The trickle charge only prevents self-discharge and cannot be used to recharge a battery that is completely discharged.

Fuel Supply System

Ensure that all fuel pipe connections are tight, secure and without leaks.

Ensure that all gas line shutoff valves are OPEN and that adequate fuel pressure is available whenever automatic operation is desired.

Battery Connection

The Standby Generator is supplied with a 12 Volt DC

33 Amp-Hour battery. It is a sealed, lead-acid rechargeable battery. It is installed in the unit and the battery cables are connected at the factory.The generator’s 15 Amp fuse has been removed to prevent the battery from discharging and the unit from starting during shipping.

If it is necessary to service the battery, proceed as follows:

1.Set generator's “AUTO/OFF/MANUAL” switch to OFF.

2.Pull service disconnect from disconnect box.

3.Remove 15 Amp fuse from control panel.

4.Service or replace battery as required.

5.Connect red battery cable to positive battery terminal (indicated by POSITIVE, POS, or (+).

6.Connect black battery cable to negative battery terminal (indicated by NEGATIVE, NEG, or (-).

FUEL SYSTEM SELECTION

The engine of your Standby Generator is factory calibrated to run on natural gas (NG). It may also be operated on liquid propane (LP).

To configure the fuel system for LP use:

1.LP fuel inlet pressure must be between 11 and 14 inches water column.

2.Set AUTO/OFF/MANUAL switch to OFF.

3.Pull service disconnect from disconnect box.

4.Remove 15 Amp fuse.

5.Change main jet in fuel mixer following instruction sheet provided in LP conversion kit.

NOTE: You will need a specialty tool, as described on page 9, to change the main jet.

6.Reinstall 15 Amp fuse.

7.Reinstall service disconnect in disconnect box.

17

Image 17
Contents Installation Start-Up Table of Contents Wear protective goggles, rubber apron, and rubber gloves Safety RulesBriggs & Stratton Power Products Standby Generator Installation Assistance Installer ResponsibilitiesIntroduction Customer ResponsibilitiesOil Fill BatteryKnow Your Standby Generator AUTO/OFF/MANUAL Know Your Control PanelOwner Orientation Installation ProceduresRequired Specialty Tools/Equipment Shipment ContentsLifting the Generator Standby Generator LocationDevice Running Watts Essential Circuit SelectionDisconnect Box Mounting Guidelines Fuel Inlet DimensionsRemovable Roof and Access Door Standby Generator unit has been factory set to Gaseous Fuel SystemLoad Fuel ConsumptionFrom Fuel 10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ft Fuel Pipe SizingWithdrawal Rate 32F 20F 10F 30F 40F Fuel Comparison ChartPhysical Properties Propane Natural Gas Generator AC Connection System To install the remote LED plateGrounding the Generator Generator Control Circuit ConnectionBefore Initial START-UP Battery ConnectionFuel System Selection Engine OilAutomatic Operation Sequence Initial START-UP no LoadTo perform the Set Exercise procedure Setting Exercise TimerInstallation Inspection Fault Detection System SpecificationsAutomatic Operation Servicing the SystemReset Fault Detection System Number of LED Flashes Fault DescriptionNo LED Discharged Battery Engine Fail To StartChanging Engine Oil and Filter Generator MaintenanceChanging Oil Changing Oil FilterStorage To Clean the GeneratorWhen Calling the Factory Problem Cause Correction TroubleshootingBriggs & Stratton Power Products Standby Generator Schematic Wiring Diagram Exploded View Main Unit Description Parts List Main UnitItems Not Illustrated KIT, Deflector Muffler Assy w/ HrdwrExploded View Enclosure Cradle Parts List EnclosureExploded View Control Panel Parts List Control Panel HARNESS,Wire DC Charge Exploded View and Parts List AlternatorADAPTER, Mounting,Alternator SCREW, M5 .8 x 10 TaptiteYear Consumer Use Years Years orManual de Instalación,Arranque y Propietario Tabla DE ContenidoConozca EL Panel DE Control Orientación Para EL Propietario Sistema DE Combustible GaseosoAdvertencia Instrucciones DE SeguridadPeligro Precaución Responsabilidades DEL Cliente IntroducciónResponsabilidades DEL Instalador Asistencia para la instalaciónEtiqueta del Motor Tapón de Llenado y Varilla Conozca SU Generador DE ReservaDe Nivel de Aceite Tapón de Llenado y Varilla de Nivel de Aceite PermiteFusible de Conozca EL Panel DE ControlDisyuntor Interruptor Fusible de 15 Amperios Protege los circuitos de control deProcedimientos DE Instalación Orientación Para EL PropietarioElevación del Generador Contenido de la CajaUbicación del Generador de Reserva Circuitos FundamentalesDispositivo Vatiaje de Selección de los Circuitos FundamentalesTecho y Puerta de Acceso Desmontables Dimensiones de la Entrada de CombustibleDirectrices de Montaje del Cuadro de Desconexión El generador de reserva viene preparado de fábrica para Sistema DE Combustible Gaseoso AdvertenciaGas Natural Vapor de PL Consumo de CombustiblePropano Líquido PL peso específico = Dimensiones de la Cañería de CombustibleGas Natural peso específico = Tasa de consumo 32F 20F 10F 30F 40F Cuadro de Comparación de CombustiblesPropiedades físicas Propano Gas natural Conexión a Tierra del Sistema Sistema de Conexión de c.a. del GeneradorInterconexiones del Circuito de Control Placa de LED RemotoSelección DEL Sistema DE Combustible Antes DEL Arranque InicialAceite de Motor Sistema de Suministro de CombustibleSecuencia DE Operación Automática Arranque Inicial SIN CargaInstale el fusible de 15 Amperios en el panel de control Fije el interruptor AUTO/OFF/MANUAL en la posiciónInspección Posterior a LA Instalación Ajuste DEL Temporizador DE EjercicioOperación Automática EspecificacionesSistema DE Detección DE FallasRestablecimiento del Sistema de Detección de Fallas Cantidad de Destellos del LED Descripción de la FallaNo se Enciende el LED Batería Descargada Baja Presión de AceiteCambio del Aceite del Motor y del Filtro Mantenimiento DEL GeneradorCambio del Filtro de Aceite Cambio del AceiteSi Llama a la Fábrica AlmacenamientoPara Limpiar el Generador Reparacion DE Averias Garantía Limitada Table DES Matières Manuel dInstallation, Démarrage et UtilisateurAvertissement Règles DE SécuritéLe contact de ces pièces risque de causer de graves brûlures Aide À Linstallation Responsabilités DE LinstallateurIntroduction Responsabilités DE LacheteurFiltre à Air Et Jauge dHuile Filtre à lHuile FAMILIARISEZ-VOUS Avec Votre Génératrice D’ÉTAT D’ATTENTEDisjoncteur Interrupteur FAMILIARISEZ-VOUS Avec LE Tableau DE Commande15 Ampères Conseils AU Propriétaire Procédures DinstallationContenu de la Boîte Emplacement du Génératrice d’état d’AttenteOutils/Équipements Spécialisés Nécessaires Soulèvement de la GénératriceAppareil Watts Sélection des Circuits EssentielsToit Amovible et Porte dAccès Dimensions de lOrifice dAdmission du CombustibleDirectives dAssemblage du Boîtier de Débranchement Le génératrice d’état d’attente a été réglé en usine pour LE Système DE Combustible Gazeux AvertissementGas Naturel Vapeur PL Consommation de CombustibleGaz de Pétrole Liquéfié GPL densité = 1,50 Grosseur du Tuyau de CombustibleGaz Naturel densité = 0,65 Propriétés physiques Propane Gaz naturel Charte de Comparaison des CombustiblesDensité 36,39 Poids† Indice d’octane Recherche 110+Pour installer la plaque DEL à distance Interconnexions du Circuit de CommandeSystème de Branchement C.A. de la Génératrice Mise à la Masse du SystèmeSélection DU Système DE Combustible Avant LE Démarrage InitialHuile à Moteur Branchement de la BatterieDémarrage Initial Sans Capteur de Prise en Charge de la Tension de ServiceSéquence DE Fonctionnement Automatique Réglez linterrupteur AUTO/OFF/MANUAL sur ManualPour Exécuter la Procédure de Réglage du Cycle dExercice Vérification InstallationRéglage DE LA Minuterie DU Cycle Dexercice Fonctionnement Automatique CaractéristiquesSystème DE Détection DES Pannes Entretien du SystèmeRéarmement du Système de Détection des Pannes Clignotements Du VoyantAucun DEL Batterie déchargée Faible Pression dHuileChangement dHuile à Moteur et de Filtre Entretien DU GénérateurChangement du filtre à huile Vidange de lHuileCommunications avec le Fabricant RemisagePour Nettoyer le Générateur Dépannage Remarques Garantie Limitée
Related manuals
Manual 84 pages 42.1 Kb

01897-0 specifications

Briggs & Stratton 01897-0 is a popular engine model renowned for its performance and durability in various applications. It is primarily used in lawn mowers and other outdoor power equipment, making it an ideal choice for homeowners and landscaping professionals alike.

One of the standout features of the 01897-0 is its powerful engine. This model is equipped with a reliable four-stroke engine that provides robust power for optimal mowing efficiency. With a displacement of 500cc, it delivers a substantial amount of torque, making it suitable for handling thick grass and tough terrains effortlessly.

The engine design incorporates several advanced technologies aimed at improving performance and extending longevity. One such feature is the overhead valve (OHV) design, which enhances airflow and increases combustion efficiency. This results in better fuel economy and lower emissions, aligning with environmental standards while providing the power needed for demanding tasks.

Another notable characteristic of the Briggs & Stratton 01897-0 is its easy-starting system. The engine is designed with a recoil starter, which allows for a quick and effortless start-up. This is especially beneficial during busy mowing seasons when efficiency is paramount.

In terms of maintenance, the 01897-0 emphasizes user convenience. It features an accessible oil drain and replacement system, facilitating simple oil changes. The air filter can also be easily accessed and replaced, ensuring the engine maintains optimal performance for many years.

Furthermore, the engine is engineered for vibration reduction, enhancing user comfort during operation. This technology helps minimize fatigue, allowing for extended mowing sessions without discomfort. The lightweight design of the engine also contributes to easier maneuverability, making it a practical choice for users of all experience levels.

Finally, Briggs & Stratton is known for its commitment to quality, and the 01897-0 is no exception. It is built to withstand the rigors of outdoor use, ensuring reliability and durability even under challenging conditions. With a reputation for excellence and a proven track record, the Briggs & Stratton 01897-0 continues to be a preferred choice for those seeking performance and reliability in outdoor power equipment. Whether for residential or commercial use, this engine model remains a popular and trusted option for efficient lawn care.