Briggs & Stratton 01897-0 owner manual Briggs & Stratton Power Products Standby Generator

Page 4

Briggs & Stratton Power Products Standby Generator

Installation, Start-Up and Owner’s Manual

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

DO NOT touch hot surfaces.

Allow equipment to cool before touching.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Essential Circuits” on page 9.

Start generator and let engine stabilize before connecting electrical loads.

WARNING

Propane and Natural Gas are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

Install the fuel supply system according to applicable fuel-gas codes.

Before placing the Standby Generator into service, the fuel system lines must be properly purged and leak tested.

After the generator is installed, you should inspect the fuel system periodically.

NO leakage is permitted.

DO NOT operate engine if smell of fuel is present or other explosive conditions exist.

DO NOT smoke around the generator.Wipe up any oil spills immediately. Ensure that no combustible materials are left in the generator compartment. Keep the area near the generator clean and free of debris.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or contact Briggs and Stratton.

Operate generator only on level surfaces.

Adequate, unobstructed flow of cooling and ventilating air is critical to correct generator operation.

The access door and roof must be installed whenever the unit is running.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

Despite the safe design of the Standby Generator, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death.

Remain alert at all times while working on this equipment. Never work on the equipment when you are physically or mentally fatigued.

DO NOT start engine with air cleaner or air cleaner cover removed.

DO NOT insert any objects through cooling slots.

DO NOT use the generator or any of its parts as a step. Stepping on the unit can cause stress and break parts.This may result in dangerous operating conditions from leaking exhaust gases, fuel leakage, oil leakage, ect..

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

4

Image 4
Contents Installation Start-Up Table of Contents Safety Rules Wear protective goggles, rubber apron, and rubber glovesBriggs & Stratton Power Products Standby Generator Installer Responsibilities Installation AssistanceIntroduction Customer ResponsibilitiesKnow Your Standby Generator BatteryOil Fill Know Your Control Panel AUTO/OFF/MANUALInstallation Procedures Owner OrientationShipment Contents Required Specialty Tools/EquipmentLifting the Generator Standby Generator LocationEssential Circuit Selection Device Running WattsRemovable Roof and Access Door Fuel Inlet DimensionsDisconnect Box Mounting Guidelines Gaseous Fuel System Standby Generator unit has been factory set toFrom Fuel Fuel ConsumptionLoad Fuel Pipe Sizing 10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ftPhysical Properties Propane Natural Gas Fuel Comparison ChartWithdrawal Rate 32F 20F 10F 30F 40F To install the remote LED plate Generator AC Connection SystemGrounding the Generator Generator Control Circuit ConnectionBattery Connection Before Initial START-UPFuel System Selection Engine OilInitial START-UP no Load Automatic Operation SequenceInstallation Inspection Setting Exercise TimerTo perform the Set Exercise procedure Specifications Fault Detection SystemAutomatic Operation Servicing the SystemNumber of LED Flashes Fault Description Reset Fault Detection SystemNo LED Discharged Battery Engine Fail To StartGenerator Maintenance Changing Engine Oil and FilterChanging Oil Changing Oil FilterWhen Calling the Factory To Clean the GeneratorStorage Troubleshooting Problem Cause CorrectionBriggs & Stratton Power Products Standby Generator Schematic Wiring Diagram Exploded View Main Unit Parts List Main Unit DescriptionItems Not Illustrated KIT, Deflector Muffler Assy w/ HrdwrExploded View Enclosure Parts List Enclosure CradleExploded View Control Panel Parts List Control Panel Exploded View and Parts List Alternator HARNESS,Wire DC ChargeADAPTER, Mounting,Alternator SCREW, M5 .8 x 10 TaptiteConsumer Use Years Years or YearTabla DE Contenido Manual de Instalación,Arranque y PropietarioConozca EL Panel DE Control Orientación Para EL Propietario Sistema DE Combustible GaseosoPeligro Instrucciones DE SeguridadAdvertencia Precaución Introducción Responsabilidades DEL ClienteResponsabilidades DEL Instalador Asistencia para la instalaciónConozca SU Generador DE Reserva Etiqueta del Motor Tapón de Llenado y VarillaDe Nivel de Aceite Tapón de Llenado y Varilla de Nivel de Aceite PermiteConozca EL Panel DE Control Fusible deDisyuntor Interruptor Fusible de 15 Amperios Protege los circuitos de control deOrientación Para EL Propietario Procedimientos DE InstalaciónContenido de la Caja Elevación del GeneradorUbicación del Generador de Reserva Circuitos FundamentalesSelección de los Circuitos Fundamentales Dispositivo Vatiaje deDirectrices de Montaje del Cuadro de Desconexión Dimensiones de la Entrada de CombustibleTecho y Puerta de Acceso Desmontables Sistema DE Combustible Gaseoso Advertencia El generador de reserva viene preparado de fábrica paraConsumo de Combustible Gas Natural Vapor de PLGas Natural peso específico = Dimensiones de la Cañería de CombustiblePropano Líquido PL peso específico = Propiedades físicas Propano Gas natural Cuadro de Comparación de CombustiblesTasa de consumo 32F 20F 10F 30F 40F Sistema de Conexión de c.a. del Generador Conexión a Tierra del SistemaInterconexiones del Circuito de Control Placa de LED RemotoAntes DEL Arranque Inicial Selección DEL Sistema DE CombustibleAceite de Motor Sistema de Suministro de CombustibleArranque Inicial SIN Carga Secuencia DE Operación AutomáticaInstale el fusible de 15 Amperios en el panel de control Fije el interruptor AUTO/OFF/MANUAL en la posiciónAjuste DEL Temporizador DE Ejercicio Inspección Posterior a LA InstalaciónEspecificaciones Operación AutomáticaSistema DE Detección DE FallasCantidad de Destellos del LED Descripción de la Falla Restablecimiento del Sistema de Detección de FallasNo se Enciende el LED Batería Descargada Baja Presión de AceiteMantenimiento DEL Generador Cambio del Aceite del Motor y del FiltroCambio del Filtro de Aceite Cambio del AceitePara Limpiar el Generador AlmacenamientoSi Llama a la Fábrica Reparacion DE Averias Garantía Limitada Manuel dInstallation, Démarrage et Utilisateur Table DES MatièresRègles DE Sécurité AvertissementLe contact de ces pièces risque de causer de graves brûlures Responsabilités DE Linstallateur Aide À LinstallationIntroduction Responsabilités DE LacheteurFAMILIARISEZ-VOUS Avec Votre Génératrice D’ÉTAT D’ATTENTE Filtre à Air Et Jauge dHuile Filtre à lHuile15 Ampères FAMILIARISEZ-VOUS Avec LE Tableau DE CommandeDisjoncteur Interrupteur Procédures Dinstallation Conseils AU PropriétaireEmplacement du Génératrice d’état d’Attente Contenu de la BoîteOutils/Équipements Spécialisés Nécessaires Soulèvement de la GénératriceSélection des Circuits Essentiels Appareil WattsDirectives dAssemblage du Boîtier de Débranchement Dimensions de lOrifice dAdmission du CombustibleToit Amovible et Porte dAccès LE Système DE Combustible Gazeux Avertissement Le génératrice d’état d’attente a été réglé en usine pourConsommation de Combustible Gas Naturel Vapeur PLGaz Naturel densité = 0,65 Grosseur du Tuyau de CombustibleGaz de Pétrole Liquéfié GPL densité = 1,50 Charte de Comparaison des Combustibles Propriétés physiques Propane Gaz naturelDensité 36,39 Poids† Indice d’octane Recherche 110+Interconnexions du Circuit de Commande Pour installer la plaque DEL à distanceSystème de Branchement C.A. de la Génératrice Mise à la Masse du SystèmeAvant LE Démarrage Initial Sélection DU Système DE CombustibleHuile à Moteur Branchement de la BatterieCapteur de Prise en Charge de la Tension de Service Démarrage Initial SansSéquence DE Fonctionnement Automatique Réglez linterrupteur AUTO/OFF/MANUAL sur ManualRéglage DE LA Minuterie DU Cycle Dexercice Vérification InstallationPour Exécuter la Procédure de Réglage du Cycle dExercice Caractéristiques Fonctionnement AutomatiqueSystème DE Détection DES Pannes Entretien du SystèmeClignotements Du Voyant Réarmement du Système de Détection des PannesAucun DEL Batterie déchargée Faible Pression dHuileEntretien DU Générateur Changement dHuile à Moteur et de FiltreChangement du filtre à huile Vidange de lHuilePour Nettoyer le Générateur RemisageCommunications avec le Fabricant Dépannage Remarques Garantie Limitée