Henny Penny OFE/OFG-323, OFE/OFG-324 manual Voltage Wattage Resistance Ohms cold, Replacement

Page 19

Model OFE/OFG-321,322,323,324

2-18. HEATING ELEMENTS

(ELECTRIC ONLY)

(Continued)3. Perform an ohm check on one element at a time, with wires disconnected from element. If the resistance is not within tolerance, replace the element.

Voltage

Wattage

Resistance Ohms (cold)

208

4800

9

230

4800

11

Replacement:

Refer to figure 2-2.

1.Drain the shortening from the frypot.

2.Remove the high limit bulb holder from the heating element inside the frypot.

3.Remove the heating element wires from the terminals by removing the nuts and washers. Label each so it can be replaced on the new element in the same position.

4.Remove the bolts from the five element spreaders. The element spreaders will now pull off the elements.

5.Remove the brass nuts and washers which secure the ends of the elements through the frypot wall.

6.Remove the heating elements from the frypot as a group by lifting the far end and sliding them up and out toward the rear of the frypot.

Always install new rubber O-rings when installing heater elements.

7.Install new heating elements with the new O-rings, terminal end first at approximately a 45° angle, slipping the terminals through the front wall of the frypot.

8.Replace the brass nuts and washers on the element terminals. Tighten the brass nuts to 30 foot lbs. of torque.

203

2-19

Image 19 Contents
Gas Units Maintenance HintsHigh Temperature Limit Control IntroductionLimit Control High TemperatureHigh Temperature Complete Control Breaker, or unplug cord at wall receptacle Power SwitchPower switch to OFF and disconnect main circuit To avoid electrical shock or property damage, moveElectric Temperature Probe ReplacementWith wrench Temperature ProbeReplacement Tighten the compression nut hand tight and then a half turnFlame Sensor Pilot / Ignitor AssemblyModel OFE/OFG-321,322,323,324 11. I/O Power Supply Speaker Assembly Vacuum SwitchSpeaker assembly emits audible signals to let the operator Filter Switch GAS Control Valve GAS Control Valve Assembly Blower Motor Assembly Heating Elements Electric only Voltage Wattage Resistance Ohms cold ReplacementTemperature Spreader Probe Heating Contactors Electric only Checkout Power Removed30 31 34 35 Mercury Contactor Contactors Electric only Heating Checkout Power SuppliedSpeaker Assembly Terminals. The tube must Never be in such a position Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power Electric UnitsLimit Control Electric Units Actuator Motor ReplacementIf applicable Autolift Actuator Motor ReplacementAutolift Actuator Motor Replacement Remove control panel Disconnect connectors from PC board Autolift PC Board Replacement