Henny Penny OFE/OFG-322 manual Power Switch, To avoid electrical shock or property damage, move

Page 5

Model OFE/OFG-321,322,323,324

2-5. POWER SWITCH

(Continued)4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel.

5.Replace with new switch, and reconnect wires to switch.

6.Replace the control panel.

2-6. TEMPERATURE PROBE The temperature probe relays the actual shortening temperature to

REPLACEMENT the control board. If it becomes disabled, “E-6B” will show in the display. Also, if the shortening temperature is out of calibration by more than 10°F or C°, the temperature probe should be replaced.

An Ohm check can be performed also. See chart on page 2-7.

1. Remove electrical power supplied to the fryer.

 

To avoid electrical shock or property damage, move the

 

power switch to OFF and disconnect main circuit

Electric

breaker, or unplug cord at wall receptacle.

2.Drain the shortening from the frypot.

3.Remove the control panel.

Gas

4.Using a 1/2" wrench, remove the nut on the compression fitting.

5.Remove the temperature probe from the frypot.

6.Follow the appropriate instructions, on the following page, depending upon the type of fryer, gas or electric.

606

2-5

Image 5 Contents
High Temperature Limit Control Maintenance HintsIntroduction Gas UnitsLimit Control High TemperatureHigh Temperature Complete Control Power switch to OFF and disconnect main circuit Power SwitchTo avoid electrical shock or property damage, move Breaker, or unplug cord at wall receptacleElectric Temperature Probe ReplacementReplacement Temperature ProbeTighten the compression nut hand tight and then a half turn With wrenchFlame Sensor Pilot / Ignitor AssemblyModel OFE/OFG-321,322,323,324 11. I/O Power Supply Speaker assembly emits audible signals to let the operator Vacuum SwitchSpeaker Assembly Filter Switch GAS Control Valve GAS Control Valve Assembly Blower Motor Assembly Heating Elements Electric only Voltage Wattage Resistance Ohms cold ReplacementTemperature Spreader Probe 30 31 34 35 Mercury Contactor Checkout Power RemovedHeating Contactors Electric only Contactors Electric only Heating Checkout Power SuppliedSpeaker Assembly Where it could accidentally touch the electrical power Line under and away from all electrical power wiresElectric Units Terminals. The tube must Never be in such a positionLimit Control Electric Units Actuator Motor ReplacementIf applicable Autolift Actuator Motor ReplacementAutolift Actuator Motor Replacement Remove control panel Disconnect connectors from PC board Autolift PC Board Replacement