Henny Penny OFE/OFG-324 manual Electric Units, Line under and away from all electrical power wires

Page 24

 

 

Model OFE/OFG-321,322,323,324

2-21. HIGH TEMPERATURE

1.

Drain the shortening from the frypot.

LIMIT CONTROL

 

 

(Electric Units)

 

 

(Continued)

2.

Remove control panel.

 

3.

Loosen small inside screw nut on capillary tube.

 

4.

Remove capillary bulb from bulb holder inside the frypot.

 

5.

Straighten the capillary tube.

 

6.

Remove larger outside nut that threads into pot wall.

 

7.

Remove the two screws that secure the high limit to the high

 

 

limit bracket.

 

8.

Remove the defective control from the control panel area.

 

9.

Insert new control and replace screws.

 

10.

Uncoil capillary tube, starting at control, and insert through

 

 

pot fitting.

 

 

To avoid electrical shock or other injury, run the capillary

 

 

line under and away from all electrical power wires and

 

 

terminals. The tube must NEVER be in such a position

 

 

where it could accidentally touch the electrical power

 

 

terminals.

 

11.

Carefully bend the capillary bulb and tube toward bulb holder

 

 

on heating elements.

 

12.

Slip capillary bulb into bulb holder on heating elements.

 

 

Pull excess capillary line from pot and tighten nut into frypot

 

 

wall.

2-24

 

203

Image 24 Contents
Maintenance Hints High Temperature Limit ControlIntroduction Gas UnitsHigh Temperature Limit ControlHigh Temperature Complete Control Power Switch Power switch to OFF and disconnect main circuitTo avoid electrical shock or property damage, move Breaker, or unplug cord at wall receptacleTemperature Probe Replacement ElectricTemperature Probe ReplacementTighten the compression nut hand tight and then a half turn With wrenchFlame Sensor Assembly Pilot / IgnitorModel OFE/OFG-321,322,323,324 11. I/O Power Supply Vacuum Switch Speaker AssemblySpeaker assembly emits audible signals to let the operator Filter Switch GAS Control Valve GAS Control Valve Assembly Blower Motor Assembly Heating Elements Electric only Replacement Voltage Wattage Resistance Ohms coldTemperature Spreader Probe Checkout Power Removed Heating Contactors Electric only30 31 34 35 Mercury Contactor Heating Checkout Power Supplied Contactors Electric onlySpeaker Assembly Line under and away from all electrical power wires Where it could accidentally touch the electrical powerElectric Units Terminals. The tube must Never be in such a positionActuator Motor Replacement Limit Control Electric UnitsAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Remove control panel Disconnect connectors from PC board Autolift PC Board Replacement