2-20. SPEAKER ASSEMBLY

(Electric Units)The speaker assembly emits audible signals to let the operator know when cooking and hold times are finished.

1. Remove electrical power supplied to unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Remove control panel.

3.Follow the speaker wire and disconnect from control board.

4.Remove the screws securing the speaker bracket to the shroud.

5.Remove the speaker from the bracket.

6.Reinstall in reverse order.

2-21. HIGH TEMPERATURE

LIMIT CONTROL The electric units, model OFE-321/2/3/4, use the same high

(Electric Units)temperature control limits as the gas units, OFG-321/2/3/4, but the mounting of the capillary tube is different on the electric units compared to the gas units.

Checkout:

Use the same procedure as in the High Limit Temperature Control (Gas) Section.

Replacement:

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle, to the frypot to be worked on. Be aware the other controls will have power.

203

2-23

Image 23 Contents
Gas Units Maintenance HintsHigh Temperature Limit Control IntroductionLimit Control High TemperatureHigh Temperature Complete Control Breaker, or unplug cord at wall receptacle Power SwitchPower switch to OFF and disconnect main circuit To avoid electrical shock or property damage, moveElectric Temperature Probe ReplacementWith wrench Temperature ProbeReplacement Tighten the compression nut hand tight and then a half turnFlame Sensor Pilot / Ignitor AssemblyModel OFE/OFG-321,322,323,324 11. I/O Power Supply Speaker assembly emits audible signals to let the operator Vacuum SwitchSpeaker Assembly Filter Switch GAS Control Valve GAS Control Valve Assembly Blower Motor Assembly Heating Elements Electric only Voltage Wattage Resistance Ohms cold ReplacementTemperature Spreader Probe 30 31 34 35 Mercury Contactor Checkout Power RemovedHeating Contactors Electric only Contactors Electric only Heating Checkout Power SuppliedSpeaker Assembly Terminals. The tube must Never be in such a position Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power Electric UnitsLimit Control Electric Units Actuator Motor ReplacementIf applicable Autolift Actuator Motor ReplacementAutolift Actuator Motor Replacement Remove control panel Disconnect connectors from PC board Autolift PC Board Replacement