Henny Penny OFE/OFG-323, OFE/OFG-324, OFE/OFG-322, OFE/OFG-321 manual High Temperature

Page 3

Model OFE/OFG-321,322,323,324

2-3 HIGH TEMPERATURE

LIMIT CONTROL (Continued)

5.Remove the bracket from the heat tube covering the high limit bulb.

6.Straighten the capillary tube behind the pot wall.

7.Pull the high limit bulb through the retainers on the heat tube.

8.Remove the larger outside nut that threads into the pot wall.

9.Remove the defective high limit from the control panel area.

10.Insert new high limit into bracket and replace wires.

11.Uncoil capillary line, starting at capillary tube, and insert through frypot wall.

To avoid electrical shock or other injury, run the capillary line under and away from all electrical power wires and terminals. The tube must never be in such a position where it could accidentally touch the electrical power terminals.

12.Insert capillary line through brackets on heat tube, and then pull back through pot wall until capillary bulb is secure in brackets.

13.Pull excess capillary line from pot and tighten nut into frypot wall.

14.With excess capillary line pulled out, tighten smaller nut.

15.Replace bracket on heat tube covering the high limit bulb.

16.Replace front panel.

17.Refill frypot with shortening.

203

2-3

Image 3 Contents
Gas Units Maintenance HintsHigh Temperature Limit Control IntroductionLimit Control High TemperatureHigh Temperature Complete Control Breaker, or unplug cord at wall receptacle Power SwitchPower switch to OFF and disconnect main circuit To avoid electrical shock or property damage, moveElectric Temperature Probe ReplacementWith wrench Temperature ProbeReplacement Tighten the compression nut hand tight and then a half turnFlame Sensor Pilot / Ignitor AssemblyModel OFE/OFG-321,322,323,324 11. I/O Power Supply Vacuum Switch Speaker AssemblySpeaker assembly emits audible signals to let the operator Filter Switch GAS Control Valve GAS Control Valve Assembly Blower Motor Assembly Heating Elements Electric only Voltage Wattage Resistance Ohms cold ReplacementTemperature Spreader Probe Checkout Power Removed Heating Contactors Electric only30 31 34 35 Mercury Contactor Contactors Electric only Heating Checkout Power SuppliedSpeaker Assembly Terminals. The tube must Never be in such a position Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power Electric UnitsLimit Control Electric Units Actuator Motor ReplacementIf applicable Autolift Actuator Motor ReplacementAutolift Actuator Motor Replacement Remove control panel Disconnect connectors from PC board Autolift PC Board Replacement