5-4TEMPERATURE SENSOR
Refer to page 4-10 for the procedure for servic-
ing the heater element assembly. NOTE: The
temperature sensor is part of the heater ele-
ment assembly.
1. Unplug dishwasher or disconnect power.
2. Disconnect the wire connector from the
CHASSIS HARNESS terminals on the
controller.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to heater
terminals 1 and 2. The meter should indi-
cate as follows:
962 @ 68°F (20°C)
1000 @ 86°F (30°C)
1200 @ 140°F (60°C)
12
WATER FILL VALVES
Refer to page 4-16 for the procedure for servic-
ing the water fill valves.
1. Unplug dishwasher or disconnect power.
2. Disconnect the wire connectors from the
water fill valve solenoid terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the u p-
per and lower water fill valve solenoid
terminals. The meter should indicate be-
tween 65 and 75 .
Solenoid
Terminals
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Upper