2-8
5. Run the house wiring through the cable
clamp and into the dishwasher.
6. Install a cable clamp (not supplied) in the
knockout opening.
7. From the house wiring, strip 1/2 (13 mm)
of insulation off of each wire.
8. Attach the supply cable to the EMI filter.
Connect the black wires together using a
wire nut. Connect the white wires together
using a wire nut.
Place the ground wire under the ground
screw. Use a 7 mm socket wrench to
securely tighten the ground screw.
.
EMI filter
ground screw wire nuts
cable clamp
9. Tighten the cable clamp and replace the
electrical cover.
10. Pull the bottom drawer runners all the way
out. Make sure the latches on the back of
each drawer runner are facing forward.
drawer
runner latch
latch
bracket
ground
screw EMI filter
strain relief
3. Remove factory-installed power cord.
Disconnect the black and white wires of
the electrical cord from the EMI filter.
Use a 7 mm socket wrench to remove the
ground screw. Remove the green ground
wire.
Use a phillips screwdriver to remove the
strain relief screw. Open the strain relief
clamp.
Pull the power supply cord through the
back of the dishwasher.
Close the strain relief clamp and replace
screw so it does not interfere with the
terminal block cover.
4. Remove the house wiring knockout.
knockout