2-16

Custom Front Panels

1. Prepare the custom front panels to speci-

fications shown below.

2. Mount the handle to the custom panel.

The screws must not extend beyond the

back surface of the panel. (The handle is

customer supplied, and the location is

customer preference.)

mark horizontal line
mark centerline
Top Panel -
1-7/16" (36.5 mm)
Bottom panel -
1-3/16" (30.2 mm)
2-5/16"
(5.9 cm)
5"
(12.7 cm)
1/4"
(6.4 mm)
end may be round
or squared off
1-9/32"
(32.6 mm)
max.
1-7/32"
(30.8 mm)
23-7/16" (59.5 cm)
9"
(22.9 cm)
15-5/8"
(39.7 cm)
medallion
cutout area
Top panel
(front view)
Medallion cutout
(front of panel)
Bottom panel
(front view)
2-1/8"
(5.4 cm)
5"
(12.7 cm)
23-7/16" (59.5 cm)
9"
(22.9 cm)
14"
(35.6 cm)
medallion
cutout area
2-13/32"
(60.8 mm)
1-13/64"
(30.6 mm)
Custom Front Panels Dimensions
Upper and lower panel minimum thickness is 5/8" (16 mm). Panel thickness above 11/16" (18 mm)
can be accommodated but product depth will increase accordingly.
Custom front panel material must be suitable for damp conditions or adequately sealed to withstand
moisture. Using a moisture resistant material can provide additional protection. Taping edges alone
may not provide adequate sealing. For painted panel, paint all rear edges to improve sealing.
NOTE: Do not cut beyond outline of
medallion cutout shown above.
Rout a 1/4" (6 mm) radius around
back side of medallion cutout.

3. Measure and mark the vertical centerline

and horizontal position line on the back of

the front panels.