WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
LID MOTOR
Refer to page
1.Unplug dishwasher or disconnect power.
2.Disconnect the lid motor connector from the chassis module at the appropriate following connectors.
P406 (Upper Left) | P404 (Upper Right) |
P403 (Lower Left) | P405 (Lower Right) |
3.Set the ohmmeter to the R x 1 scale.
4.Touch the ohmmeter test leads to the lid
motor connector terminals. The meter should indicate between 55 and 200 Ω.
POWER RESISTOR & HEATER
Refer to page
1.Unplug dishwasher or disconnect power.
2.Disconnect the wire connector from the CHASSIS HARNESS terminals on the controller.
3.Set the ohmmeter to the R x 1 scale.
4.To test the power resistor, touch the ohmmeter test leads to heater terminals 4
and 9. The meter should indicate between 25 and 35 Ω.
5.To test the heater, touch the ohmmeter
test leads to heater terminals 6 and 9. The meter should indicate between 23 and 29 Ω.
1 | 6 | 9 |
4 |
Connector