2-7. FLAME SENSOR

The flame sensor recognizes the pilot flame and allows gas to

(Gas Units)

continue to the pilot. The flame sensor must send a minimum of

 

two (2) micro amps to the ignition module. The pilot flame should

 

be split in two by the flame sensor, causing the flame sensor to be

 

bright red in color.

 

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle..

2.To access flame sensor, open the filter doors in the front of the unit. Follow the small gauge yellow wire running to the sensor behind the pilot assembly.

3.Disconnect the flame sense wire from the flame sensor.

4.Using a pair of needle nosed pliers, pull the flame sensor out of the pilot assembly bracket.

5.Insert new flame sensor and reconnect flame sensor wire.

6.Turn power on and check fryer.

2-8

203

Image 8 Contents
Maintenance Hints High Temperature Limit ControlIntroduction Gas UnitsHigh Temperature Limit ControlHigh Temperature Complete Control Power Switch Power switch to OFF and disconnect main circuitTo avoid electrical shock or property damage, move Breaker, or unplug cord at wall receptacleTemperature Probe Replacement ElectricTemperature Probe ReplacementTighten the compression nut hand tight and then a half turn With wrenchFlame Sensor Assembly Pilot / IgnitorModel OFE/OFG-321,322,323,324 11. I/O Power Supply Speaker assembly emits audible signals to let the operator Vacuum SwitchSpeaker Assembly Filter Switch GAS Control Valve GAS Control Valve Assembly Blower Motor Assembly Heating Elements Electric only Replacement Voltage Wattage Resistance Ohms coldTemperature Spreader Probe 30 31 34 35 Mercury Contactor Checkout Power RemovedHeating Contactors Electric only Heating Checkout Power Supplied Contactors Electric onlySpeaker Assembly Line under and away from all electrical power wires Where it could accidentally touch the electrical powerElectric Units Terminals. The tube must Never be in such a positionActuator Motor Replacement Limit Control Electric UnitsAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Remove control panel Disconnect connectors from PC board Autolift PC Board Replacement