Henny Penny OFE/OFG-321, OFE/OFG-324, OFE/OFG-322, OFE/OFG-323 manual GAS Control Valve

Page 14

Model OFE/OFG-321,322,323,324

2-15. FILTER SWITCH

(Continued)2. Remove the control panel above the switch.

3.Label and remove the wires from the switch. With test instrument, check across the terminals of the switch with the switch in the ON position, and then in the OFF position. With the switch in the ON position, the circuit should be closed. With the switch in the OFF position, the circuit should be open. If the switch checks defective, replace it by continuing with

this

procedure.

4.With wires removed from the switch, push in on tabs on the switch and remove switch from the panel.

5.Push new switch into panel and reconnect wires.

2-16. GAS CONTROL VALVE

ASSEMBLYThe gas control valve assembly controls the flow of gas to the pilot and the main burner. The valve has two 24 volt coils, which are regulated by terminals P and M on the valve. The C terminal is the common terminal. For gas flow to the pilot, 24 VAC must be present between the P and C terminals. For gas flow to the main burner, 24 VAC must be present between the M and C terminals.

TO AVOID PERSONAL INJURY OR PROPERTY

DAMAGE, BEFORE STARTING THIS

PROCEDURE, MOVE THE MAIN POWER SWITCH

TO THE OFF POSITION. DISCONNECT THE MAIN

CIRCUIT BREAKERS AT THE CIRCUIT BREAKER

BOX OR UNPLUG SERVICE CORD FROM WALL

RECEPTACLE. TURN OFF THE MAIN GAS

SUPPLY TO THE FRYER AND DISCONNECT AND

CAP THE MAIN SUPPLY LINE TO FRYER, OR

POSSIBLE EXPLOSION COULD RESULT.

1.Remove control panel assembly.

2.Remove wires from gas control valve.

2-14

203

Image 14 Contents
Introduction Maintenance HintsHigh Temperature Limit Control Gas UnitsHigh Temperature Limit ControlHigh Temperature Complete Control To avoid electrical shock or property damage, move Power SwitchPower switch to OFF and disconnect main circuit Breaker, or unplug cord at wall receptacleTemperature Probe Replacement ElectricTighten the compression nut hand tight and then a half turn Temperature ProbeReplacement With wrenchFlame Sensor Assembly Pilot / IgnitorModel OFE/OFG-321,322,323,324 11. I/O Power Supply Speaker assembly emits audible signals to let the operator Vacuum SwitchSpeaker Assembly Filter Switch GAS Control Valve GAS Control Valve Assembly Blower Motor Assembly Heating Elements Electric only Replacement Voltage Wattage Resistance Ohms coldTemperature Spreader Probe 30 31 34 35 Mercury Contactor Checkout Power RemovedHeating Contactors Electric only Heating Checkout Power Supplied Contactors Electric onlySpeaker Assembly Electric Units Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power Terminals. The tube must Never be in such a positionActuator Motor Replacement Limit Control Electric UnitsAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Remove control panel Disconnect connectors from PC board Autolift PC Board Replacement