Henny Penny BFR/BCR-350, BCC/BCR-140 Refrigerant Information, Refrigeration, Capacities, BFR-350

Page 10

Henny PennyModel BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

2-5. REFRIGERANT

 

 

 

 

INFORMATION

 

 

Design Pressure

 

 

 

 

 

Refrigerant Type

Amount of Refrig.

High

Low

 

 

 

 

 

BCC-140

R404A

6 lbs. (2.7 kg)

406 psig

102psig

 

 

 

(28 bar)

(7 bar)

 

 

 

 

 

BCC-175

R404A

5.5 lbs. (2.4 kg)

406 psig

102 psig

 

 

 

(28 bar)

(7 bar)

 

 

 

 

 

2-6. REFRIGERATION

BCC/BCR-140

CAPACITIES

-4oF (-20oC) at 6,800 BTU/hr (2.0 kw)

 

32o F (0o C) at 16,000 BTU/hr (4.7 kw)

 

BCC/BCR-175

 

-4oF (-20oC) at 11,300 BTU/hr (3.3 kw)

 

32o F (0o C) at 38,800 BTU/hr (9.0 kw)

 

BCR-350

 

-4oF (-20oC) at 25,000 BTU/hr (7.3 kw)

 

32o F (0o C) at 58,000 BTU/hr (17.0 kw)

 

BFR-350

 

-4oF (-20oC) at 81,900 BTU/hr (24.0 kw)

 

-40oF (-40oC) at 35,500 BTU/hr (10.4 kw)

2-4

201

Image 10
Contents Page Henny Penny Blast Chiller/Freezer Limited Warranty for Henny Penny Appliances Table Ofcontents Proper Care FeaturesBlast Chiller AssistanceSafety Introduction UnpackingBCC-175 ElectricalBCC-140 BCR-140Location BFRCapacities Refrigerant InformationRefrigeration BFR-350Operating Controls Description FunctionOnly applicable On BFR unitsHenny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Basic Operation Start-upBasic Operation Temperature conversion chart is provided for your ConvenienceDE-ICING Daily CleaningMonthly BCC-140 Only Cleaning Seasonal or Prolonged ShutdownProgramming Not Available at this timeMaximum duration of de-icing cycle minutes. Press International Only. a Frigiprobe sensor temperature Duration of time the temperatures, in 9Above, must remain at before the alarms will sound To prevent freezing of the product. Press the AlarmBlast chilling, high side air temperature limit, when using Blast chilling, low side air temperature limit, when usingFrigiprobe, in of this section. Press the Alarm Frigiprobe, end of cycle temperature setting. PressTemperature that the buzzer will sound when the product Frigiprobe temperature for when the buzzer sounds atStart of a cycle. Press the Alarm button 17 times, Has reached the danger zone temperature, and must beTroubleshooting Display Cause CorrectionAlarms TroubleshootingProblem Cause Correction 100 Troubleshooting Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 BCC BCR QuantityDescription 140 175 350 Part Page CPE-USALCO Page Henny Penny International Distributor Network Oman