SECTION 2. INSTALLATION

2-1. INTRODUCTION

This section provides the installation for the Henny Penny

 

Blast Chiller.

 

NOTE

 

Installation of this unit should be performed only by a

 

qualified service technician.

 

Do not puncture the skin of the Blast Chiller with drills or

 

screws, as component damage or electrical shock could

 

result. Also, if the unit is shipped with a compressor, Do Not

 

lay the unit on its side. If the unit has been on its side, the unit

 

must be in an upright position for at least an hour before

 

power is applied to the unit. Check all components for signs

 

of being loose or damaged, and make sure the system has

 

refrigerant. Failure to follow these instructions may cause

 

damage to the components.

2-2. UNPACKING

The Henny Penny Blast Chiller has been tested, inspected, and

 

expertly packed to insure arrival at its destination in the best pos

 

sible condition. The cabinet rests on a wooden skid and is then

 

packed inside a wooden box with sufficient padding to withstand

 

normal shipping treatment.

 

NOTE

 

Any shipping damage should be noted in the presence of

 

the delivery agent and signed prior to his or her depar-

 

ture.

 

To remove the Henny Penny Blast Chiller from the box, you

 

should:

 

1. Carefully cut banding straps.

 

2. Remove box from around unit.

 

3. Lift the unit off the skid.

 

The BCC/BCR-140 and BCC/BCR-175 weighs between

 

400 (181 kg) and 550 lbs (249 kg), and the BFR and

 

BCR-350 weigh approximately 770 lbs (350 kg). Take care

 

when lifting units to prevent personnal injury.

201

2-1

Image 7
Contents Page Henny Penny Blast Chiller/Freezer Limited Warranty for Henny Penny Appliances Table Ofcontents Assistance FeaturesBlast Chiller Proper CareSafety Unpacking IntroductionBCR-140 ElectricalBCC-140 BCC-175BFR LocationBFR-350 Refrigerant InformationRefrigeration CapacitiesDescription Function Operating ControlsOn BFR units Only applicableHenny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Start-up Basic OperationBasic Operation Convenience Temperature conversion chart is provided for yourDE-ICING Daily CleaningMonthly BCC-140 Only Seasonal or Prolonged Shutdown CleaningNot Available at this time ProgrammingMaximum duration of de-icing cycle minutes. Press To prevent freezing of the product. Press the Alarm Duration of time the temperatures, in 9Above, must remain at before the alarms will sound International Only. a Frigiprobe sensor temperatureFrigiprobe, end of cycle temperature setting. Press Blast chilling, low side air temperature limit, when usingFrigiprobe, in of this section. Press the Alarm Blast chilling, high side air temperature limit, when usingHas reached the danger zone temperature, and must be Frigiprobe temperature for when the buzzer sounds atStart of a cycle. Press the Alarm button 17 times, Temperature that the buzzer will sound when the productDisplay Cause Correction TroubleshootingAlarms TroubleshootingProblem Cause Correction 100 Troubleshooting Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 BCC BCR QuantityDescription 140 175 350 Part Page CPE-USALCO Page Henny Penny International Distributor Network Oman