2-3. ELECTRICAL

Refer to the table below for electrical ratings for both models.

(Continued)

Model No.

Volts

Watts

Amps

Freq.

Phase

 

BCC-140

200

4700

18

50/60

3

 

 

208-240

4700

18

60

3

 

 

230

4700

20

50

1

 

BCC-175

200

5800

20

50/60

3

 

 

208-240

5800

20

60

3

 

 

400

5800

9

50

3N

 

BCR-140

208-240

2400

12

60

1

 

 

230

2400

10

50

1

 

 

200

2400

12

50-60

1

 

BCR-175

200

2400

12

50/60

1

 

 

208-240

2400

12

60

1

 

 

230

2400

12

50

1

 

BFR &

200

4100

15

50/60

3

 

BCR-350

208-240

4100

15

60

3

 

 

400

4100

10

50

3N

2-4. LOCATION

The Blast Chillers should be placed in an area where the doors can

 

be opened, for loading and unloading, without interruption. For

 

proper operation, the cabinet must be level.

 

 

For maximum efficiency, if the air temperature of the premises is more than 100° F (38° C), the room should have adequate ventilation, taking into account for the heat emitted by the unit.

Clearances should be as follows:

BCC/BCR-140

Top

16 in. (400 mm) for air circulation

 

Left Side ...

4 in. (100 mm) for air circulation

 

Right Side . 8 in. (200 mm) for air circulation

 

Back

4 in (100 mm) for air circulation

 

Front

26 3/8 in (668 mm) for door swing

BCC/BCR-175

Top

16 in. (400 mm) for air circulation

 

Sides

3 in. (70 mm) for air circulation

 

Front

33 3/8 in. (847 mm) for door swing

BFR &

Top

16 in. (400 mm) for air circulation

BCR-350

Sides

3 in. (70 mm) for air circulation

Pass Thru- Front and Back ... 38 1/8 in (970 mm) for door swing

Solid Back-Front

38 1/8 in. (970 mm) for door swing

 

Back

4 in. (100 mm) for air circulation

201

2-3

Image 9
Contents Page Henny Penny Blast Chiller/Freezer Limited Warranty for Henny Penny Appliances Table Ofcontents Blast Chiller FeaturesProper Care AssistanceSafety Unpacking IntroductionBCC-140 ElectricalBCC-175 BCR-140BFR LocationRefrigeration Refrigerant InformationCapacities BFR-350Description Function Operating ControlsOn BFR units Only applicableHenny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Start-up Basic OperationBasic Operation Convenience Temperature conversion chart is provided for yourDE-ICING Cleaning DailyMonthly BCC-140 Only Seasonal or Prolonged Shutdown CleaningNot Available at this time ProgrammingMaximum duration of de-icing cycle minutes. Press Above, must remain at before the alarms will sound Duration of time the temperatures, in 9International Only. a Frigiprobe sensor temperature To prevent freezing of the product. Press the AlarmFrigiprobe, in of this section. Press the Alarm Blast chilling, low side air temperature limit, when usingBlast chilling, high side air temperature limit, when using Frigiprobe, end of cycle temperature setting. PressStart of a cycle. Press the Alarm button 17 times, Frigiprobe temperature for when the buzzer sounds atTemperature that the buzzer will sound when the product Has reached the danger zone temperature, and must beDisplay Cause Correction TroubleshootingTroubleshooting AlarmsProblem Cause Correction 100 Troubleshooting Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Quantity BCC BCRDescription 140 175 350 Part Page CPE-USALCO Page Henny Penny International Distributor Network Oman