Henny Penny BCC/BCR-175, BCC/BCR-140 Blast chilling, low side air temperature limit, when using

Page 23

Henny Penny

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

3-7. PROGRAMMING

14.

Blast chilling, low side air temperature limit, when using

(Continued)

 

the Frigiprobe, in step 12 of this section. Press the Alarm

 

 

 

 

 

button 14 times and the low side air temperature, at which

 

 

20

 

 

the compressor cycles on and off, will show in the display.

 

 

 

 

 

This temperature is used in preventing the product from

 

 

 

 

 

freezing, while in the chilling mode, which is described in

 

 

 

 

 

step 12.

 

 

 

 

 

The factory setting is -4ºF (-20ºC), but can be changed to a

 

 

 

 

 

maximum setting of 32ºF (0ºC), and a minimum setting of

 

 

 

 

 

-31ºF (-35ºC), by using the Up and Down buttons.

 

 

 

15.

Blast chilling, high side air temperature limit, when using

21

 

 

 

 

 

 

the Frigiprobe, in step 12 of this section. Press the Alarm

 

 

 

 

 

button 15 times and the high side air temperature, at which

 

 

 

 

 

the compressor cycles on and off, will show in the display.

 

 

 

 

 

This temperature is used in preventing the product from

 

 

 

 

 

freezing, while in the chilling mode, which is described in

 

 

 

 

 

step 12.

 

 

 

 

 

The factory setting is 32ºF (0ºC), but can be changed to a

 

 

 

 

 

maximum setting of 50ºF (10ºC), and a minimum setting of

 

 

 

 

 

23ºF (-5ºC), by using the Up and Down buttons.

 

 

 

16.

Frigiprobe, end of cycle temperature setting. Press the

22

 

 

 

 

 

 

Alarm button 16 times, and the temperature at which ends

 

 

 

 

 

the food probe cycle and starts the hold cycle, will show in

 

 

 

 

 

the display.

The factory setting is 39ºF (4ºC), but can be changed to a maximum setting of 50ºF (10ºC), and a minimum setting of 32ºF (0ºC), by using the Up and Down buttons.

NOTE

The maximum settings for U.S.A. is 39ºF (4ºC), and for

England is 37ºF (3ºC).

3-13

300

Image 23
Contents Page Henny Penny Blast Chiller/Freezer Limited Warranty for Henny Penny Appliances Table Ofcontents Assistance FeaturesBlast Chiller Proper CareSafety Unpacking IntroductionBCR-140 ElectricalBCC-140 BCC-175BFR LocationBFR-350 Refrigerant InformationRefrigeration CapacitiesDescription Function Operating ControlsOn BFR units Only applicableHenny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Start-up Basic OperationBasic Operation Convenience Temperature conversion chart is provided for yourDE-ICING Monthly BCC-140 Only CleaningDaily Seasonal or Prolonged Shutdown CleaningNot Available at this time ProgrammingMaximum duration of de-icing cycle minutes. Press To prevent freezing of the product. Press the Alarm Duration of time the temperatures, in 9Above, must remain at before the alarms will sound International Only. a Frigiprobe sensor temperatureFrigiprobe, end of cycle temperature setting. Press Blast chilling, low side air temperature limit, when usingFrigiprobe, in of this section. Press the Alarm Blast chilling, high side air temperature limit, when usingHas reached the danger zone temperature, and must be Frigiprobe temperature for when the buzzer sounds atStart of a cycle. Press the Alarm button 17 times, Temperature that the buzzer will sound when the productDisplay Cause Correction TroubleshootingProblem Cause Correction TroubleshootingAlarms 100 Troubleshooting Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Description 140 175 350 QuantityBCC BCR Part Page CPE-USALCO Page Henny Penny International Distributor Network Oman