SECTION 3. OPERATION

3-1. INTRODUCTION

 

This section provides operating procedures for the Blast Chiller.

 

 

 

Sections 1, 2, and 3 should be read, and all instructions should be

 

 

 

followed before operating the cabinet.

 

 

 

This section contains an explanation of all controls and compo-

 

 

 

nents and information on operating procedures and daily

 

 

 

maintenance.

 

 

 

If the blast chillers (that have compressors shipped with them)

 

 

 

have been laid on its side, the unit must be sitting upright for at

 

 

 

least an hour before applying power to the unit. Check all

 

 

 

components for signs of being loose or damaged, and make

 

 

 

sure the system has refrigerant. Failure to follow these

 

 

 

instructions may cause damage to the components. Failure to

 

 

 

follow these instructions could cause damage to the compres

 

 

 

sor.

3-2. OPERATING CONTROLS

Pages 3-1 to 3-4 identifies and describes the function of all the

 

 

 

operating controls.

Fig.

Item

Description

Function

No.

No.

 

 

3-1

1

On/Off Button

The On/Off button, when pressed, is a button on the

 

 

 

control panel that starts a chilling cycle. It also must be

 

 

 

pressed before any changes to the controls can be made,

 

 

 

and to start and stop the De-ice cycle.

3-1

2

DigitalDisplay

The Digital Display shows the temperatures, the time

 

 

 

(in a timing cycle), and the information in the technical

 

 

 

mode.

3-1

3

Up and Down

The Up and Down Arrows are used when changing

 

 

Arrows

times or settings.

3-1

4

Alarm Button

The Alarm button is used to stop the optional alarm buzzer

 

 

 

and to enter the technical mode.

3-1

5

Temp Button

The Temp button is used to select either the chilling

 

 

mode.

 

3-1

6

De-ice Button

The De-ice button is used to remove ice that may have

 

 

 

formed on the evaporator during a chilling cycle.

3-1

100

Image 11
Contents Page Henny Penny Blast Chiller/Freezer Limited Warranty for Henny Penny Appliances Table Ofcontents Assistance FeaturesBlast Chiller Proper CareSafety Unpacking IntroductionBCR-140 ElectricalBCC-140 BCC-175BFR LocationBFR-350 Refrigerant InformationRefrigeration CapacitiesDescription Function Operating ControlsOn BFR units Only applicableHenny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Start-up Basic OperationBasic Operation Convenience Temperature conversion chart is provided for yourDE-ICING Monthly BCC-140 Only CleaningDaily Seasonal or Prolonged Shutdown CleaningNot Available at this time ProgrammingMaximum duration of de-icing cycle minutes. Press To prevent freezing of the product. Press the Alarm Duration of time the temperatures, in 9Above, must remain at before the alarms will sound International Only. a Frigiprobe sensor temperatureFrigiprobe, end of cycle temperature setting. Press Blast chilling, low side air temperature limit, when usingFrigiprobe, in of this section. Press the Alarm Blast chilling, high side air temperature limit, when usingHas reached the danger zone temperature, and must be Frigiprobe temperature for when the buzzer sounds atStart of a cycle. Press the Alarm button 17 times, Temperature that the buzzer will sound when the productDisplay Cause Correction TroubleshootingProblem Cause Correction TroubleshootingAlarms 100 Troubleshooting Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Description 140 175 350 QuantityBCC BCR Part Page CPE-USALCO Page Henny Penny International Distributor Network Oman