Henny PennyModel
4-2. TROUBLESHOOTING
(Continued) |
|
|
Problem | Cause | Correction |
|
|
|
Green compressor indicator | Voltage across terminals |
|
light off and compressor | of control board: |
|
is working. | - Control board relay bad | Replace control board. |
| No voltage across terminals |
|
| of control board: |
|
| - Faulty contactor.Replace contactor. |
|
|
|
|
Green fan indicator light | Voltage across terminals |
|
on and fan(s) not working. | control board. |
|
| - Fan or capacitor bad | Replace fan or its capacitor. |
| - Fan | Allow the fan motor to cool to |
|
| see if the fan comes back on. |
|
| If the fan does not come back |
|
| on, or it keeps tripping, re- |
|
| place the fan. |
| No voltage across terminals |
|
| of control board: |
|
| - Faulty control board relay. | Replace control board. |
|
|
|
All indicator lights off and | Check electrical supply. | Plug unit into receptacle, or |
On/Off switch will not |
| reset wall circuit breaker. |
operate. | Fuse of control board blown. | Change the fuse. |
| ||
| No voltage from the control | Change the control board. |
| board transformer. |
|
| Connector between the control | Check the connection. |
| board and display board not |
|
| connected properly. |
|
| Bad wire in the connector between | Replace the connector. |
| the control board and display |
|
| board. |
|
|
|
|
|
|
|