Henny Penny BCC/BCR-140, BFR/BCR-350 manual Frigiprobe temperature for when the buzzer sounds at

Page 24

Henny Penny

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

3-7. PROGRAMMING

17.

Frigiprobe temperature for when the buzzer sounds at

(Continued)

 

the start of a cycle. Press the Alarm button 17 times, and

 

 

 

 

the temperature that the buzzer will sound when the product

 

23

 

 

has reached the “danger zone” temperature, and must be

 

 

 

 

cooled to a “safe” temperature within the recommended

 

 

 

 

time, will be shown in the display.

The factory setting is 140ºF (60ºC), but can be changed to a maximum setting of 176ºF (80ºC), and a minimum setting of 122ºF (50ºC), by using the Up and Down buttons.

30

NOTE

The settings for the U.S.A. must be 140ºF (60ºC) and for England, 158ºF (70ºC).

18.Selecting Fahrenheit or Celsius. Press the Alarm button 18 times and ºF or ºC will show in the display. Use the Up and Down buttons to toggle from ºF to ºC, or vice versa.

100

3-14

Image 24
Contents Page Henny Penny Blast Chiller/Freezer Limited Warranty for Henny Penny Appliances Table Ofcontents Features Blast ChillerProper Care AssistanceSafety Introduction UnpackingElectrical BCC-140BCC-175 BCR-140Location BFRRefrigerant Information RefrigerationCapacities BFR-350Operating Controls Description FunctionOnly applicable On BFR unitsHenny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Basic Operation Start-upBasic Operation Temperature conversion chart is provided for your ConvenienceDE-ICING Cleaning DailyMonthly BCC-140 Only Cleaning Seasonal or Prolonged ShutdownProgramming Not Available at this timeMaximum duration of de-icing cycle minutes. Press Duration of time the temperatures, in 9 Above, must remain at before the alarms will soundInternational Only. a Frigiprobe sensor temperature To prevent freezing of the product. Press the AlarmBlast chilling, low side air temperature limit, when using Frigiprobe, in of this section. Press the AlarmBlast chilling, high side air temperature limit, when using Frigiprobe, end of cycle temperature setting. PressFrigiprobe temperature for when the buzzer sounds at Start of a cycle. Press the Alarm button 17 times,Temperature that the buzzer will sound when the product Has reached the danger zone temperature, and must beTroubleshooting Display Cause CorrectionTroubleshooting AlarmsProblem Cause Correction 100 Troubleshooting Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 100 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 Quantity BCC BCRDescription 140 175 350 Part Page CPE-USALCO Page Henny Penny International Distributor Network Oman