Hoshizaki FS-1022MLH-C service manual

Page 29

9)Refill Cycle/Low Water Safety Cycle "GM", "COMP", and "WTRIN" LEDs are on. As ice is produced, the water level in the reservoir drops. UF/S opens. Nothing happens at this time. When LF/S opens, WV energizes, 90-second low water safety timer (fill timer) starts. GMR (X2 on CB), GM, GMPR, EH, PDS, MC, Comp, and FMR continue. When LF/S closes, nothing happens at this time. When UF/S closes, WV de-energizes, 90-second low water safety timer (fill timer) terminates, and 30minute freeze timer starts.

If UF/S remains open 90 seconds after WV energizes (LF/S opens) (fill timer exceeded), a 90-second shutdown cycle starts. CB X1 relay de-energizes, de- energizing PDS. Refrigeration circuit low-side pressure drops to 9 PSIG, opening CLPS. CLPS opens de-energizing MC, Comp, and FMR. CB signals a 1-beep alarm every 5 seconds. 90-second purge timer starts. GMR (X2 on CB), GM, GMPR, and EH continue. 90-second purge timer terminates, GMR (X2 on CB), GM, GMPR, and EH deenergizes. WV and 1-beep alarm continue until UF/S closes.

Diagnosis – Check that "WTRIN" LED is on. If not, check that LF/S is open. See "IV.E. Float Switch Check and Cleaning." If LF/S is open and "WTRIN" LED is off, CB is bad and must be replaced. If "WTRIN" LED is on, check that the reservoir fills. If not, check for water supply line shutoff valve closed, clogged water filters, and clogged WV screen. Next, check 24VAC to WV from CB K2 connector pin #8 white/brown (W/BR) wire to a light blue (LBU) neutral wire. Check for continuity through WV solenoid. If open, replace WV. If WV is energized and refill exceeds 90-second low water safety timer (fill timer) with no water in the reservoir, check for DV leaking. If reservoir is full and overflowing check that UF/S closes. If not, check UF/S continuity, red (R) wire to black (BK) wire.

Clean or replace if necessary. See "IV.E. Float Switch Check and Cleaning."

Note: Each time UF/S closes, 30-minute freeze timer starts. The 30-minute freeze timer resets when UF/S closes again. If UF/S does not close again within 30 minutes, CB shuts down the unit and sounds a 5-beep alarm every 5 seconds. See

"II.C.2. LED Lights and Audible Alarm Safeties."

10)Shutdown – See "IV.D. Bin Control Check."

Legend: CB–control board; CLPS–control low-pressure switch; Comp–compressor; DV–drain valve; EH–evaporator heater; FMR–fan motorremote; GM–gear motor; GMPR–gear motor protect relay; GMR–gear motor relay; HM–headmaster; HPS–highpressure switch; IS–infrared sensor; LF/S–lower float switch; MC–magnetic contactor; MBC–mechanical backup bin control; PDS–pump-down solenoid valve; SLPS–safety low-pressure switch; UF/S–upper float switch; WV–inlet water valve

29

Image 29
Contents SRC-10H Hoshizaki AMERICA, INC Contents Page Serious injury Important Safety InformationIndicates important information about the use and care UnitFor SRC FS-1022MLH-C Specifications IcemakerSRC-10H Condensing UnitIcemaker FS-1022MLH-C II. General Information ConstructionCondensing Unit a SRC-10H Icemaking Unit Sequence Cycles and Shutdown Sequence of OperationDrain Cycle Shutdown Cycle Sequence Flow Chart Control Board Sequence Flow Chart FS-1022MLH-C/SRC-10HControl Board Control Board Control Board LayoutNo. of Beeps Type of Alarm Reset Options Every 5 sec LED Lights and Audible Alarm SafetiesSequence Step Energized Components Min MaxSeconds 1.6 minutes Factory Default Controls and AdjustmentsS1 Dip Switch Setting Infrared Sensor Shutdown Delay S1 Dip Switch Setting Dispense Time S1 Dip Switch Setting Drain Timer IntervalBackup S1 Dip Switch MechanicalShutdown Delay Bin ControlIII Wiring Diagrams High-Pressure Switch Control Low-Pressure SwitchSafety Low-Pressure Switch Manual Reset FS-1022MLH-C with SRC-10H Performance DataIce Production Check IV. Service DiagnosisDiagnostic Procedure Page Page Page Control Board Check 5VDC Page Infrared Sensor Check Bin Control CheckMechanical Backup Bin Control Check Page Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Page No Ice Production Possible Cause Startup Diagnostic ChartsNo Ice Production No Ice Production Possible Cause Shutdown Service for Refrigerant Lines Removal and Replacement of ComponentsEvacuation and Recharge R-404A Refrigerant RecoveryBrazing Component Important Notes for Component ReplacementEvaporator Assembly Components. See Fig Evaporator Assembly Upper Bearing Wear Check Removal and Replacement of CutterRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator Page Removal and Replacement of Gear Motor 6b. Lower HousingPage Cleaning and Sanitizing Instructions VI. Cleaning and MaintenanceCleaning Solution Cleaning ProcedureFloat Switch Assembly Reservoir Cover Sanitizing Procedure Initial Sanitizing SolutionSanitizing Procedure Final Maintenance Frequency Area Task Maintenance ScheduleDrain the evaporator Preparing the Icemaker for Long StorageRemove the water from the icemaker water supply line