9)Remove the object covering IS. If you removed IS housing from the base, replace it in its correct position, and secure it with the thumbscrew.
10)Move the power switch to the "OFF" position. Unplug the icemaker from the electrical outlet, then proceed to "IV.D.2. Mechanical Backup Bin Control Check."
| Infrared Sensor LED |
| Infrared Sensor |
| Thumbscrew |
Infrared Sensor LED |
|
| Infrared Sensor |
| Housing |
Fig. 3 | Lens |
2. Mechanical Backup Bin Control Check
When the actuator paddle is not engaged MBC is closed and the icemaker produces ice.
a)Mechanical Backup Bin Control: S1 dip switch 7 placed in the "ON" position, MBC is used as a backup bin control safety. When ice fills the chute and engages the actuator paddle, MBC opens and CB shuts down the icemaker within 10 seconds and sounds a
b)
MBC is used as a
1)Remove the front panel.
2)Move the power switch to the "OFF" position, then unplug the unit from the electrical outlet.
3)Remove the strap connecting the spout to the chute assembly. See Fig. 4. Pull up the chute assembly slightly so that you can access the actuator paddle located in the top of the chute.
4)Plug the unit into the electrical outlet.
5)Move the power switch to the "ON" position to start the automatic icemaking process.
Strap |
| Proximity Switch |
|
| Actuator Paddle |
Spout |
| Chute Assembly |
|
| |
| Strap | Fig. 4 |
|
|
34