Hoshizaki FS-1022MLH-C service manual Specifications Icemaker

Page 7

I. Specifications

A. Icemaker

1. FS-1022MLH-C

AC SUPPLY VOLTAGE

115/60/1

 

 

 

 

GEAR MOTOR

120 V

3 FLA

1/4 HP

 

 

OTHER

 

120 V

0.03A

 

 

 

MAXIMUM FUSE SIZE

15 A

 

 

 

 

MAX. HACR BREAKER (USA ONLY)

15 A

 

 

 

 

MAX. CIRC. BREAKER (CANADA ONLY)

15 A

 

 

 

 

MINIMUM CIRCUIT AMPACITY

15 A

 

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

 

PER 24 HR.

 

Temp.(°F)

50

70

90

 

lb./day (kg/day)

70

*830 (380)

805 (365)

785 (355)

 

Reference without *marks

80

765 (350)

750 (340)

730 (330)

 

 

 

90

710 (325)

*705 (320)

680 (310)

 

SHAPE OF ICE

100

660 (300)

650 (295)

*600 (275)

 

Cubelet

 

 

 

 

ICE QUALITY

Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)

APPROXIMATE STORAGE CAPACITY

N/A

 

 

 

 

ELECTRIC & WATER CONSUMPTION

90/70°F

 

70/50°F

 

 

ELECTRIC

W (kWH/100 lbs.)

1745 (5.96)

 

1713 (4.94)

FS-1022MLH-C & SRC-10H

ELECTRIC

W (kWH/100 lbs.)

331 (1.13)

 

345 (1.00)

FS-1022MLH-C ONLY

POTABLE WATER

84 (12)

 

100 (12)

 

 

gal./24HR (gal./100 lb.)

 

 

 

 

 

EXTERIOR DIMENSIONS (WxDxH)

22"x16.5"x26" (560x417x657mm)

 

 

EXTERIOR FINISH

Stainless Steel

 

 

 

WEIGHT

 

Net 126 lb. (57 kg), Shipping 166 lb. (75 kg)

CONNECTIONS - ELECTRIC

Cord Connection

 

 

 

 

- WATER SUPPLY

Inlet 1/2" FPT

 

 

 

 

- DRAIN

Outlet 3/4" FPT

 

 

 

 

- REFRIGERATION

Suction line 1-1/16-12 UNF Fitting (#10 PARKER)

 

CIRCUIT

Liquid line

5/8-18 UNF Fitting (#6 PARKER)

ICE MAKING SYSTEM

Auger type

 

 

 

 

HARVESTING SYSTEM

Direct Driven Auger (1/4 HP Gear Motor)

 

 

ICE MAKING WATER CONTROL

Float Switch

 

 

 

COOLING WATER CONTROL

N/A

 

 

 

 

BIN CONTROL SYSTEM (Primary)

Photoelctric Sensor

 

 

 

BIN CONTROL SYSTEM (Secondary)

Mechanical Bin Control (Proximity Switch)

CONDENSING UNIT

Air-Cooled Remote Condensing unit SRC-10H Required

EVAPORATOR

Copper Tube on Cylinder

 

 

 

REFRIGERANT CONTROL

Thermostatic Expansion Valve

 

 

 

 

Headmaster (C.P.R.) on SRC-10H (210 PSI)

REFRIGERANT CHARGE

R-404A, 8 lb. 6 oz. (3800 g)

 

 

 

 

Icemaker: 4 oz. (113 g)

 

 

 

 

 

Condensing Unit: 8 lb. 2 oz. (3687 g)

 

 

DESIGN PRESSURE

High 427 PSIG, Low 230 PSIG

 

 

P.C. BOARD CIRCUIT PROTECTION

Fuse (1A)

 

 

 

 

GEAR MOTOR PROTECTION

Fuse (3A)

 

 

 

 

LOW WATER PROTECTION

Float Switch and Timer

 

 

 

ACCESSORIES -SUPPLIED

Spare Fuse

 

 

 

 

 

-REQUIRED

Ice Storage Bin

 

 

 

 

 

Condensing Unit: SRC-10H

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

104-127VAC

 

 

AMBIENT TEMP.

 

45-100°F

 

 

WATER SUPPLY TEMP.

 

45-90°F

 

 

WATER SUPPLY PRESSURE

10-113 PSIG

Note: We reserve the right to make changes in specifications and design without prior notice.

7

Image 7
Contents SRC-10H Hoshizaki AMERICA, INC Contents Page Unit Important Safety InformationSerious injury Indicates important information about the use and careFor SRC FS-1022MLH-C Specifications IcemakerSRC-10H Condensing UnitIcemaker FS-1022MLH-C II. General Information ConstructionCondensing Unit a SRC-10H Icemaking Unit Sequence Cycles and Shutdown Sequence of OperationDrain Cycle Shutdown Cycle Sequence Flow Chart Control Board Sequence Flow Chart FS-1022MLH-C/SRC-10HControl Board Control Board Control Board LayoutEnergized Components Min Max LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Reset Options Every 5 sec Sequence StepS1 Dip Switch Setting Infrared Sensor Shutdown Delay Controls and AdjustmentsSeconds 1.6 minutes Factory Default S1 Dip Switch Setting Dispense Time S1 Dip Switch Setting Drain Timer IntervalBin Control S1 Dip Switch MechanicalBackup Shutdown DelayIII Wiring Diagrams Safety Low-Pressure Switch Manual Reset Control Low-Pressure SwitchHigh-Pressure Switch FS-1022MLH-C with SRC-10H Performance DataDiagnostic Procedure IV. Service DiagnosisIce Production Check Page Page Page Control Board Check 5VDC Page Infrared Sensor Check Bin Control CheckMechanical Backup Bin Control Check Page Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Page No Ice Production Diagnostic ChartsNo Ice Production Possible Cause Startup No Ice Production Possible Cause Shutdown Service for Refrigerant Lines Removal and Replacement of ComponentsBrazing Refrigerant RecoveryEvacuation and Recharge R-404A Evaporator Assembly Components. See Fig Important Notes for Component ReplacementComponent Evaporator Assembly Upper Bearing Wear Check Removal and Replacement of CutterRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator Page Removal and Replacement of Gear Motor 6b. Lower HousingPage Cleaning Procedure VI. Cleaning and MaintenanceCleaning and Sanitizing Instructions Cleaning SolutionFloat Switch Assembly Reservoir Cover Sanitizing Procedure Initial Sanitizing SolutionSanitizing Procedure Final Maintenance Frequency Area Task Maintenance ScheduleRemove the water from the icemaker water supply line Preparing the Icemaker for Long StorageDrain the evaporator