Hoshizaki FS-1022MLH-C service manual Sanitizing Procedure Final

Page 54

3)Pour the sanitizing solution over the extruding head until the evaporator assembly and the reservoir are full and the solution starts to overflow into the drain pan.

4)Remove the proximity switch from the chute assembly, then remove the chute assembly from the icemaker.

5)Remove the packing at the bottom of the ice chute. Remove the 3 ties and the chute insulation.

6)Remove the 2 baffles.

7)Remove the plate and the packing from the top of the ice chute, then remove the backup bin control assembly by sliding it slightly towards the chute opening and lifting it off.

8)Disassemble the backup bin control assembly by removing the 2 snap pins, shaft, and actuator.

9)Soak the spout, O-ring, packings, chute, baffles, plate, and backup bin control assembly in the sanitizing solution for 10 minutes then wipe them down.

10)Rinse the parts thoroughly with clean water.

CAUTION

If the solution is left on these parts, they will rust.

11) Replace all parts in their correct positions.

IMPORTANT

When installing the baffles, make sure that the bent surface (the one without the studs) faces the actuator so that the bent surface can guide the ice to the center of the actuator.

12)Replace all panels except the front panel in their correct positions. Move the control switch to the "ICE" position, then plug the unit back in. Move the power switch to the "ON" position, then replace the front panel in its correct position. Make ice using the solution until the icemaker stops making ice.

13)Remove the front panel, then move the power switch to the "OFF" position. Move the control switch to the "DRAIN" position, then move the power switch back to the "ON" position. Replace the front panel in its correct position.

14)Allow the water system to drain for 5 minutes.

15)Remove the front panel. Move the power switch to the "OFF" position, then unplug the unit from the electrical outlet.

5.Sanitizing Procedure - Final

1)Mix a new batch of the sanitizing solution.

2)Make sure the power switch is in the "OFF" position, the unit is unplugged from the electrical outlet, and the water supply line shut-off valve is closed. Remove the top panel.

3)Remove the strap connecting the spout to the chute assembly, then remove the spout.

54

Image 54
Contents SRC-10H Hoshizaki AMERICA, INC Contents Page Indicates important information about the use and care Important Safety InformationSerious injury UnitFor SRC Specifications Icemaker FS-1022MLH-CCondensing Unit SRC-10HII. General Information Construction Icemaker FS-1022MLH-CCondensing Unit a SRC-10H Icemaking Unit Sequence of Operation Sequence Cycles and ShutdownDrain Cycle Shutdown Cycle Control Board Sequence Flow Chart FS-1022MLH-C/SRC-10H Sequence Flow ChartControl Board Control Board Layout Control BoardSequence Step LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Reset Options Every 5 sec Energized Components Min MaxControls and Adjustments S1 Dip Switch Setting Infrared Sensor Shutdown DelaySeconds 1.6 minutes Factory Default S1 Dip Switch Setting Drain Timer Interval S1 Dip Switch Setting Dispense TimeShutdown Delay S1 Dip Switch MechanicalBackup Bin ControlIII Wiring Diagrams Control Low-Pressure Switch Safety Low-Pressure Switch Manual ResetHigh-Pressure Switch Performance Data FS-1022MLH-C with SRC-10HIV. Service Diagnosis Diagnostic ProcedureIce Production Check Page Page Page Control Board Check 5VDC Page Bin Control Check Infrared Sensor CheckMechanical Backup Bin Control Check Page Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Page Diagnostic Charts No Ice ProductionNo Ice Production Possible Cause Startup No Ice Production Possible Cause Shutdown Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery BrazingEvacuation and Recharge R-404A Important Notes for Component Replacement Evaporator Assembly Components. See FigComponent Evaporator Assembly Removal and Replacement of Cutter Upper Bearing Wear CheckRemoval and Replacement of Extruding Head Removal and Replacement of AugerRemoval and Replacement of Evaporator Page 6b. Lower Housing Removal and Replacement of Gear MotorPage Cleaning Solution VI. Cleaning and MaintenanceCleaning and Sanitizing Instructions Cleaning ProcedureFloat Switch Assembly Reservoir Cover Sanitizing Solution Sanitizing Procedure InitialSanitizing Procedure Final Maintenance Maintenance Schedule Frequency Area TaskPreparing the Icemaker for Long Storage Remove the water from the icemaker water supply lineDrain the evaporator