Hoshizaki FS-1022MLH-C service manual

Page 37

3)Wipe down F/S assembly with a mixture of 1 part Hoshizaki "Scale Away" and 25 parts warm water. Rinse the assembly thoroughly with clean water.

4)While not necessary, the floats can be removed from the shaft during cleaning. If you remove them, note that the blue float is on top (UF/S) and the white float is on bottom (LF/S). The floats must be installed with the magnets inside them towards the top of the switch. See Fig. 6. Installing the floats upside down will affect the timing of F/S operation.

5)Rinse the float switch assembly thoroughly with clean water and replace in its correct position.

6)Plug the unit into the electrical outlet, then move the power switch to the "ON" position to start the automatic icemaking process.

7)Replace the front panel in its correct position.

Legend: CB–control board; F/S–float switch; GM–gear motor; LF/S–lower float switch; UF/S–upper float switch

Float Switch Assembly

Reservoir Cover

Reservoir

Fig. 5

Red (R) (upper float switch)

Black (BK) (common)

Dark Blue (DBU) (lower float switch)

Magnet (towards top)

Upper Float (blue)

Magnet (towards top)

Lower Float (white)

Spring Retainer Clip

Plastic Retainer Clip

Fig. 6

37

Image 37
Contents SRC-10H Hoshizaki AMERICA, INC Contents Page Serious injury Important Safety InformationIndicates important information about the use and care UnitFor SRC FS-1022MLH-C Specifications IcemakerSRC-10H Condensing UnitIcemaker FS-1022MLH-C II. General Information ConstructionCondensing Unit a SRC-10H Icemaking Unit Sequence Cycles and Shutdown Sequence of OperationDrain Cycle Shutdown Cycle Sequence Flow Chart Control Board Sequence Flow Chart FS-1022MLH-C/SRC-10HControl Board Control Board Control Board LayoutNo. of Beeps Type of Alarm Reset Options Every 5 sec LED Lights and Audible Alarm SafetiesSequence Step Energized Components Min MaxS1 Dip Switch Setting Infrared Sensor Shutdown Delay Controls and AdjustmentsSeconds 1.6 minutes Factory Default S1 Dip Switch Setting Dispense Time S1 Dip Switch Setting Drain Timer IntervalBackup S1 Dip Switch MechanicalShutdown Delay Bin ControlIII Wiring Diagrams Safety Low-Pressure Switch Manual Reset Control Low-Pressure SwitchHigh-Pressure Switch FS-1022MLH-C with SRC-10H Performance DataDiagnostic Procedure IV. Service DiagnosisIce Production Check Page Page Page Control Board Check 5VDC Page Infrared Sensor Check Bin Control CheckMechanical Backup Bin Control Check Page Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Page No Ice Production Diagnostic ChartsNo Ice Production Possible Cause Startup No Ice Production Possible Cause Shutdown Service for Refrigerant Lines Removal and Replacement of ComponentsBrazing Refrigerant RecoveryEvacuation and Recharge R-404A Evaporator Assembly Components. See Fig Important Notes for Component ReplacementComponent Evaporator Assembly Upper Bearing Wear Check Removal and Replacement of CutterRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator Page Removal and Replacement of Gear Motor 6b. Lower HousingPage Cleaning and Sanitizing Instructions VI. Cleaning and MaintenanceCleaning Solution Cleaning ProcedureFloat Switch Assembly Reservoir Cover Sanitizing Procedure Initial Sanitizing SolutionSanitizing Procedure Final Maintenance Frequency Area Task Maintenance ScheduleRemove the water from the icemaker water supply line Preparing the Icemaker for Long StorageDrain the evaporator