Hoshizaki FS-1022MLH-C Controls and Adjustments, Seconds 1.6 minutes Factory Default

Page 19

3. Controls and Adjustments

CAUTION

Dip switches are factory set. Failure to maintain factory settings may adversely affect performance and warranty coverage. For more information, contact Hoshizaki Technical Support at 1-800-233-1940.

a)Default Dip Switch Settings

The S1 dip switch settings are factory-set to the following positions:

S1 Dip Switch No.

1

2

3

4

5

6

7

8

9

10

FS-1022MLH-C

ON

OFF

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

Normally off (factory use)

Mechanical Backup Bin Control Shutdown Delay Bin Control Selector

Continuous Dispensing Timer

(DCM models only, do not adjust on modular icemakers)

Drain Frequency Control

Infrared Sensor Shutdown Delay

b)Infrared Sensor Shutdown Delay (S1 dip switch 1, 2, 3)

Infrared sensor shutdown delay is the delay between the infrared sensor detecting ice

(yellow LED flashing or steady) and the start of the shutdown sequence. For dispenser unit applications, the ice level at shutoff may need to be adjusted depending on the dispenser agitation or dispense method. Increasing the shutdown delay setting allows for a higher level of ice in the bin before the icemaker shuts down. For a typical dispenser unit application, a 100second shutdown delay is recommended. When used with a standard Hoshizaki storage bin, any shutdown delay setting is acceptable.

WARNING

Increasing the shutdown delay allows a higher level of ice in the dispensing unit/storage bin before shutdown. This could lead to icemaker movement or ice overflow.

S1 Dip Switch Setting

Infrared Sensor Shutdown Delay

 

 

 

No. 1

No. 2

No. 3

 

 

 

 

 

OFF

OFF

OFF

0 Seconds

 

 

 

 

ON

OFF

OFF

100 Seconds (1.6 minutes) (Factory Default)

OFF

ON

OFF

1100 Seconds (18.3 minutes)

 

 

 

 

OFF

OFF

ON

1650 Seconds (27.5 minutes)

 

 

 

 

ON

ON

OFF

2200 Seconds (36.7 minutes)

 

 

 

 

OFF

ON

ON

0 Seconds

 

 

 

 

ON

ON

ON

0 Seconds

19

Image 19
Contents SRC-10H Hoshizaki AMERICA, INC Contents Page Unit Important Safety InformationSerious injury Indicates important information about the use and careFor SRC FS-1022MLH-C Specifications IcemakerSRC-10H Condensing UnitIcemaker FS-1022MLH-C II. General Information ConstructionCondensing Unit a SRC-10H Icemaking Unit Sequence Cycles and Shutdown Sequence of OperationDrain Cycle Shutdown Cycle Sequence Flow Chart Control Board Sequence Flow Chart FS-1022MLH-C/SRC-10HControl Board Control Board Control Board LayoutEnergized Components Min Max LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Reset Options Every 5 sec Sequence StepS1 Dip Switch Setting Infrared Sensor Shutdown Delay Controls and AdjustmentsSeconds 1.6 minutes Factory Default S1 Dip Switch Setting Dispense Time S1 Dip Switch Setting Drain Timer IntervalBin Control S1 Dip Switch MechanicalBackup Shutdown DelayIII Wiring Diagrams Safety Low-Pressure Switch Manual Reset Control Low-Pressure SwitchHigh-Pressure Switch FS-1022MLH-C with SRC-10H Performance DataDiagnostic Procedure IV. Service DiagnosisIce Production Check Page Page Page Control Board Check 5VDC Page Infrared Sensor Check Bin Control CheckMechanical Backup Bin Control Check Page Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Page No Ice Production Diagnostic ChartsNo Ice Production Possible Cause Startup No Ice Production Possible Cause Shutdown Service for Refrigerant Lines Removal and Replacement of ComponentsBrazing Refrigerant RecoveryEvacuation and Recharge R-404A Evaporator Assembly Components. See Fig Important Notes for Component ReplacementComponent Evaporator Assembly Upper Bearing Wear Check Removal and Replacement of CutterRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator Page Removal and Replacement of Gear Motor 6b. Lower HousingPage Cleaning Procedure VI. Cleaning and MaintenanceCleaning and Sanitizing Instructions Cleaning SolutionFloat Switch Assembly Reservoir Cover Sanitizing Procedure Initial Sanitizing SolutionSanitizing Procedure Final Maintenance Frequency Area Task Maintenance ScheduleRemove the water from the icemaker water supply line Preparing the Icemaker for Long StorageDrain the evaporator