B. Condensing Unit

1. SRC-10H

AC SUPPLY VOLTAGE

208-230/60/1 (3 Wire w/Neutral for 115VAC)

COMPRESSOR

208-230V

9.6 RLA

46 LRA

FAN MOTOR

120 V

3 A

MAX

OTHER

120 V

0.5 A

 

MAXIMUM FUSE SIZE

20 A

 

 

MAX. HACR BREAKER (USA ONLY)

20 A

 

 

MAX. CIRC. BREAKER (CANADA ONLY)

20 A

 

 

MINIMUM CIRCUIT AMPACITY

20 A

 

 

EXTERIOR DIMENSIONS (WxDxH)

28"x23"x19" (711x280x485mm)

 

DIMENSIONS WITH LEGS (WxDxH)

28"x23"x36" (711x280x915mm)

 

EXTERIOR FINISH

Galvanized Steel

 

 

WEIGHT (Approximate)

Net 143 lb. (65 kg), Shipping 169 lb. (77 kg)

CONNECTIONS - ELECTRIC

Permanent - Connection

 

- REFRIGERATION

Suction Line 1 1/16"-12 UNF Fitting (#10 PARKER)

CIRCUIT

Liquid Line 5/8"-18 UNF Fitting (#6 PARKER)

COMPRESSOR

Hermetic, Model RS80-C2E-CAV

CONDENSER

Air-Cooled Fin and Tube Type

 

FAN MOTOR PROTECTION

Thermal Protector

 

REFRIGERATION PROTECTION

Auto-Reset High-Pressure Switch, Manual Low-Pressure Switch

REFRIGERANT CONTROL

Headmaster (C.P.R.) (210 PSI)

 

PUMPDOWN CONTROL

Auto-Reset Low-Pressure Switch

REFRIGERANT CHARGE

R-404A, 8 lb. 6 oz. (3800 g)

 

 

Condensing Unit: 8 lb. 2 oz. (3687 g)

 

Icemaker: 4 oz. (113 g)

 

DESIGN PRESSURE

High 427 PSIG, Low 230 PSIG

 

COMPRESSOR PROTECTION

Internal Protector

 

 

ACCESSORIES -SUPPLIED

Leg

 

2 pcs.

 

Hex Head Bolt w/ Washer 8X16

8 pcs.

 

Hex Nut

 

8 pcs.

OPERATING CONDITIONS

VOLTAGE RANGE

187-253 VAC

 

AMBIENT TEMP.

 

-4-122°F

 

HEAT OF REJECTION

10500 BTU/hr

Note: We reserve the right to make changes in specifications

and design without prior

notice.

 

 

 

8

Image 8
Contents SRC-10H Hoshizaki AMERICA, INC Contents Page Important Safety Information Serious injuryIndicates important information about the use and care UnitFor SRC Specifications Icemaker FS-1022MLH-CCondensing Unit SRC-10HII. General Information Construction Icemaker FS-1022MLH-CCondensing Unit a SRC-10H Icemaking Unit Sequence of Operation Sequence Cycles and ShutdownDrain Cycle Shutdown Cycle Control Board Sequence Flow Chart FS-1022MLH-C/SRC-10H Sequence Flow ChartControl Board Control Board Layout Control BoardLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Reset Options Every 5 secSequence Step Energized Components Min MaxSeconds 1.6 minutes Factory Default Controls and AdjustmentsS1 Dip Switch Setting Infrared Sensor Shutdown Delay S1 Dip Switch Setting Drain Timer Interval S1 Dip Switch Setting Dispense TimeS1 Dip Switch Mechanical BackupShutdown Delay Bin ControlIII Wiring Diagrams High-Pressure Switch Control Low-Pressure SwitchSafety Low-Pressure Switch Manual Reset Performance Data FS-1022MLH-C with SRC-10HIce Production Check IV. Service DiagnosisDiagnostic Procedure Page Page Page Control Board Check 5VDC Page Bin Control Check Infrared Sensor CheckMechanical Backup Bin Control Check Page Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Page No Ice Production Possible Cause Startup Diagnostic ChartsNo Ice Production No Ice Production Possible Cause Shutdown Removal and Replacement of Components Service for Refrigerant LinesEvacuation and Recharge R-404A Refrigerant RecoveryBrazing Component Important Notes for Component ReplacementEvaporator Assembly Components. See Fig Evaporator Assembly Removal and Replacement of Cutter Upper Bearing Wear CheckRemoval and Replacement of Extruding Head Removal and Replacement of AugerRemoval and Replacement of Evaporator Page 6b. Lower Housing Removal and Replacement of Gear MotorPage VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Solution Cleaning ProcedureFloat Switch Assembly Reservoir Cover Sanitizing Solution Sanitizing Procedure InitialSanitizing Procedure Final Maintenance Maintenance Schedule Frequency Area TaskDrain the evaporator Preparing the Icemaker for Long StorageRemove the water from the icemaker water supply line