Hoshizaki dcm-75ibah service manual Spout Inlet Water Valve Water Supply Float

Page 11

2. DCM-751BWH(-OS)

Spout

 

Inlet Water Valve

Water Supply

Float

 

Switch

Water Level

ReservoirEvaporator

Overflow

Drier

Thermostatic

Expansion Valve

To Drain

Drain Valve

Gear Motor

Dispense Water Valve

Water In

Water Out

Water-Cooled Condenser

Water Regulating

Valve

High-Pressure Switch

Compressor

Refrigeration Circuit

Water Circuit

11

Image 11
Contents DCM-751BAH-OS DCM-751BWH-OS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page DCM-751BAH-OS Construction and Water/Refrigeration Circuit DiagramsDCM-751BWH-OS Ice Making Unit Water/Refrigeration Circuit Diagrams Spout Inlet Water Valve Water Supply Float Diagnosis Control Board Sequence Flow Chart DCM-751BH-OSChart OperationIce Production Check Service DiagnosisDiagnostic Procedure Page Page Page Page Control Board Check 5VDC CB K9 Connector Component Pin # Wire Color 5VDC CB K9 Connector See FigHigh-Pressure Switch HPS Bin Control BC 5VDC CB K8 Connector See Fig5VDC CB K8 Connector Component Pin # Wire Color Gear Motor Protect Relay Gmpr5VDC 0VDC Portion Signal #5 R Red K4 pin closest 5VDC Power Supply #3 W/BK Connector Pin # Wire Color Neutral LBU Open Closed 24VAC CB K2 ConnectorBin Control Check Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Page No Ice Production Possible Cause Startup Diagnostic TablesNo Ice Production Shutdown No Ice Production Possible CauseWater Dispense-Push Button Ice/Water DispensingIce Dispense-Push Button Ice Dispense-Opti-ServeIII. Controls and Adjustments DCM-751BH Control Board LayoutDCM-751BH-OS K2 Connector Drain Valve #10 W/BUEnergized Components Min Max LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Reset Options Every 5 sec Icemaking Sequence Sequence StepDrain Frequency Control S1 dip switch Settings and AdjustmentsDefault Dip Switch Settings Infrared Sensor Shutdown Delay S1 dip switch 1, 2Factory Use S1 Dip Switch 9 Continuous Dispensing Timer S1 dip switch 5Bin Control Selector S1 dip switch Bin Control Shutdown Delay S1 dip switchDrain Power Switch, Control Switch, and Dispense Mode SwitchICE OFFPortion Dispense Mode SwitchContinuous Service for Refrigerant Lines IV. Removal and Replacement of ComponentsEvacuation and Recharge R-404A Refrigerant RecoveryBrazing Evaporator Assembly Components. See Fig Important Notes for Component ReplacementEvaporator Assembly Upper Bearing Wear Check Icemaking UnitRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator 5b. Lower Housing Removal and Replacement of Gear Motor Dispense and Agitating Motors Dispense ComponentsDispense Auger and Agitator Frequency Area Task MaintenanceMaintenance Schedule VI. Preparing the Appliance for Periods of Non-Use Page VII. Disposal DCM-751BAH VIII. Technical Information Specification SheetsDesign without prior Potable Water WATER-COOLED Condenser DCM-751BWH779 758 Reference without *marks 738 719 ICE Production Performance Data800 363 Wiring Diagrams DCM-751BH-OS