Hoshizaki dcm-75ibah Control Board Sequence Flow Chart DCM-751BH-OS, Operation, Diagnosis

Page 12

"F-A" Control Board Sequence Flow Chart

DCM-751B_H(-OS)

4. 1-in-12 Drain Cycle - Although the factory default 1-in-1 drain cycle is recommended, a 1-in-12 drain cycle is available. For 1-in-12 drain cycle sequence, see "3. 1-in-12 Drain Cycle & Restart (optional)."

A. Sequence of

II. Sequence of

1. Startup

Power Switch "ON" Control Switch in "ICE" Safety Switch closed "POWER OK" LED on

1. Fill Cycle

Maximum

90 seconds

2. Ice Purge Cycle

To bypass, press the "SERVICE" button after GM starts.

5 sec. 5 minutes

3. Freeze Cycle

1-in-1 drain cycle. DV energizes for 2 seconds every hour

(S1 Dip Switch 4).

Refill

Does not affect operation.

Maximum

 

 

90 seconds

Low Water Safety

When UFS closes,

90 sec. FT exceeded

alarm resets and

1-beep alarm sounds

2. Ice Purge Cycle

90 sec. PT starts

starts.

90 seconds

 

 

 

 

 

 

 

FT

PT

terminates

 

exceeded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OperationFlow

Operation and

 

WV energized

LFS closed

GM energized

Comp energized

UFS open

LFS closed

1-beep alarm sounds

1-beep alarm continues

 

UFS closed

GMPR energized

FM energized

LFS open

UFS closed

PT starts

WV energized

 

FT starts (90 sec.)

 

FT terminates

 

GM energized

FT starts (90 sec.)

FT terminates

UFS open

GM de-energized

 

 

 

 

 

WV de-energized

GMPR energized

WV energized

WV de-energized

WV energized

GMPR de-energized

12

If Fill > 90 sec. FT

 

 

Comp energized

Comp energized

Comp de-energized

 

1-beep alarm sounds

 

 

FM energized

FM energized

FM de-energized

 

 

WV energized

 

 

 

GM energized

GM energized

GM energized

 

 

When UFS closes

 

 

GMPR energized

GMPR energized

GMPR energized

 

 

alarm resets and

 

 

 

 

 

 

2. Ice Purge Cycle starts.

Chart

Service

 

Diagnosis

2.Bin Control Shutdown & Restart

BC open (BC actuator paddle engaged)

1. Bin Full

2. Icemaker Off

3. Icemaker Restart

6 to 10 sec.

 

Ice level lowered

to "2. Ice Purge Cycle" above

All Components de-energizedBC closed

(BC actuator paddle disengaged)

Legend: BC-bin control Comp-compressorDC-drain cycle DT-drain timer DV-drain valve FM-fan motor

3. 1-in-12 Drain Cycle

1. DT Initiates DC 2. Ice Purge Cycle

3. 10-Minute Drain 4. Icemaker Restart

& Restart (optional)

5 minutes

 

to "1. Fill Cycle" above

(S1 dip switch 4)

 

 

 

 

 

Comp de-energized

DV energized

10-min. DT terminates

 

FM de-energized

GM de-energized

DV de-energized

 

GM energized

GMPR de-energized

1-in-12 DT reset

 

GMPR energized

 

 

FT-fill timer (low water safety) GM-gear motor GMPR-gear motor protect relay LFS-lower float switch PT-purge timer

UFS-upper float switch WV-inlet water valve

Image 12
Contents DCM-751BAH-OS DCM-751BWH-OS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Construction and Water/Refrigeration Circuit Diagrams DCM-751BAH-OSDCM-751BWH-OS Ice Making Unit Water/Refrigeration Circuit Diagrams Spout Inlet Water Valve Water Supply Float Control Board Sequence Flow Chart DCM-751BH-OS ChartOperation DiagnosisService Diagnosis Diagnostic ProcedureIce Production Check Page Page Page Page Control Board Check 5VDC CB K9 Connector See Fig High-Pressure Switch HPS5VDC CB K9 Connector Component Pin # Wire Color 5VDC CB K8 Connector See Fig 5VDC CB K8 Connector Component Pin # Wire ColorGear Motor Protect Relay Gmpr Bin Control BC5VDC 0VDC Portion Signal #5 R Red K4 pin closest 5VDC Power Supply #3 W/BK 24VAC CB K2 Connector Connector Pin # Wire Color Neutral LBU Open ClosedBin Control Check Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Page Diagnostic Tables No Ice ProductionNo Ice Production Possible Cause Startup No Ice Production Possible Cause ShutdownIce/Water Dispensing Ice Dispense-Push ButtonIce Dispense-Opti-Serve Water Dispense-Push ButtonIII. Controls and Adjustments Control Board Layout DCM-751BHK2 Connector Drain Valve #10 W/BU DCM-751BH-OSLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Reset Options Every 5 secIcemaking Sequence Sequence Step Energized Components Min MaxSettings and Adjustments Default Dip Switch SettingsInfrared Sensor Shutdown Delay S1 dip switch 1, 2 Drain Frequency Control S1 dip switchContinuous Dispensing Timer S1 dip switch 5 Bin Control Selector S1 dip switchBin Control Shutdown Delay S1 dip switch Factory Use S1 Dip Switch 9Power Switch, Control Switch, and Dispense Mode Switch ICEOFF DrainDispense Mode Switch ContinuousPortion IV. Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery BrazingEvacuation and Recharge R-404A Important Notes for Component Replacement Evaporator Assembly Components. See FigEvaporator Assembly Icemaking Unit Upper Bearing Wear CheckRemoval and Replacement of Extruding Head Removal and Replacement of AugerRemoval and Replacement of Evaporator 5b. Lower Housing Removal and Replacement of Gear Motor Dispense Components Dispense Auger and AgitatorDispense and Agitating Motors Maintenance Maintenance ScheduleFrequency Area Task VI. Preparing the Appliance for Periods of Non-Use Page VII. Disposal VIII. Technical Information Specification Sheets DCM-751BAHDesign without prior DCM-751BWH Potable Water WATER-COOLED Condenser779 758 Reference without *marks 738 719 Performance Data ICE Production800 363 Wiring Diagrams DCM-751BH-OS