Hoshizaki dcm-75ibah Power Switch, Control Switch, and Dispense Mode Switch, Ice, Off, Drain

Page 38

D. Power Switch, Control Switch, and Dispense Mode Switch

The power switch, control switch, and dispense mode switch are used to control the operation of the appliance.

1. Power Switch

 

WARNING! The power switch does not turn off all power

 

supply to the unit. 115VAC power supply is present on

 

control board K1 connector pin #2 (BR) and control board

 

X1 relay (BR) when the power switch is in the "OFF"

Fig. 10

position.

2. Control Switch

The control switch has 3 positions, "ICE," "OFF," and "DRAIN." See Fig. 11.

a) ICE

When the control switch is in the "ICE" position, 24VAC is directed to control board K8 connector pin #1. 24VAC is present between control board K8 connector pins #1 (power) and

pin #2 (neutral).

b) OFF

When the control switch is in the "OFF" position, 24VAC is broken to control board K8 connector pin #1.

CONTROL

ICE

OFF

DRAIN

Fig. 11

c) DRAIN

When the control switch is in the "DRAIN" position, 24VAC is directed to control board K8 connector pin #1. 24VAC is present between control board K8 connector pins #1 (power) and

pin #2 (neutral). Also, a 5VDC circuit is closed on control board K9 connector pins #1 and #2. This energizes an internal relay on the control board which allows 24VAC to the drain valve from control board connector K2 pin #10.

38

Image 38
Contents DCM-751BAH-OS DCM-751BWH-OS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Construction and Water/Refrigeration Circuit Diagrams DCM-751BAH-OSDCM-751BWH-OS Ice Making Unit Water/Refrigeration Circuit Diagrams Spout Inlet Water Valve Water Supply Float Operation Control Board Sequence Flow Chart DCM-751BH-OSChart DiagnosisIce Production Check Service DiagnosisDiagnostic Procedure Page Page Page Page Control Board Check 5VDC CB K9 Connector Component Pin # Wire Color 5VDC CB K9 Connector See FigHigh-Pressure Switch HPS Gear Motor Protect Relay Gmpr 5VDC CB K8 Connector See Fig5VDC CB K8 Connector Component Pin # Wire Color Bin Control BC5VDC 0VDC Portion Signal #5 R Red K4 pin closest 5VDC Power Supply #3 W/BK 24VAC CB K2 Connector Connector Pin # Wire Color Neutral LBU Open ClosedBin Control Check Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Page No Ice Production Possible Cause Startup Diagnostic TablesNo Ice Production No Ice Production Possible Cause ShutdownIce Dispense-Opti-Serve Ice/Water DispensingIce Dispense-Push Button Water Dispense-Push ButtonIII. Controls and Adjustments Control Board Layout DCM-751BHK2 Connector Drain Valve #10 W/BU DCM-751BH-OSIcemaking Sequence Sequence Step LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Reset Options Every 5 sec Energized Components Min MaxInfrared Sensor Shutdown Delay S1 dip switch 1, 2 Settings and AdjustmentsDefault Dip Switch Settings Drain Frequency Control S1 dip switchBin Control Shutdown Delay S1 dip switch Continuous Dispensing Timer S1 dip switch 5Bin Control Selector S1 dip switch Factory Use S1 Dip Switch 9OFF Power Switch, Control Switch, and Dispense Mode SwitchICE DrainPortion Dispense Mode SwitchContinuous IV. Removal and Replacement of Components Service for Refrigerant LinesEvacuation and Recharge R-404A Refrigerant RecoveryBrazing Important Notes for Component Replacement Evaporator Assembly Components. See FigEvaporator Assembly Icemaking Unit Upper Bearing Wear CheckRemoval and Replacement of Extruding Head Removal and Replacement of AugerRemoval and Replacement of Evaporator 5b. Lower Housing Removal and Replacement of Gear Motor Dispense and Agitating Motors Dispense ComponentsDispense Auger and Agitator Frequency Area Task MaintenanceMaintenance Schedule VI. Preparing the Appliance for Periods of Non-Use Page VII. Disposal VIII. Technical Information Specification Sheets DCM-751BAHDesign without prior DCM-751BWH Potable Water WATER-COOLED Condenser779 758 Reference without *marks 738 719 Performance Data ICE Production800 363 Wiring Diagrams DCM-751BH-OS