2. DCM-751BWH(-OS)
APPROXIMATE | Ambient |
|
|
| Water Temp. (°F) |
|
|
| ||
ICE PRODUCTION | Temp. (°F) |
| 50 |
| 70 |
| 90 | |||
PER 24 HR. | 70 | 800 |
| 363 | 779 |
| 353 | 758 |
| 344 |
| 80 | 738 |
| 335 | 719 |
| 326 | 700 |
| 317 |
| 90 | 681 |
| 309 | 685 |
| 311 | 646 |
| 293 |
lb./day kg/day | 100 | 629 |
| 285 | 612 |
| 278 | 563 |
| 255 |
APPROXIMATE ELECTRIC | 70 | 1274 |
| 1275 |
| 1276 |
| |||
CONSUMPTION | 80 | 1277 |
| 1278 |
| 1279 |
| |||
| 90 | 1280 |
| 1281 |
| 1284 |
| |||
watts | 100 | 1286 |
| 1289 |
| 1291 |
| |||
APPROXIMATE WATER | 70 | 474 |
| 1.79 | 513 |
| 1.94 | 686 |
| 2.60 |
CONSUMPTION PER 24 HR. | 80 | 504 |
| 1.91 | 565 |
| 2.14 | 804 |
| 3.04 |
| 90 | 513 |
| 1.94 | 609 |
| 2.31 | 823 |
| 3.11 |
gal./day l/day | 100 | 623 |
| 2.36 | 659 |
| 2.49 | 1019 |
| 3.86 |
EVAPORATOR OUTLET TEMP. | 70 | 12 |
| 12 |
| 12 |
| |||
| 80 | 12 |
| 12 |
| 12 |
| |||
| 90 | 12 |
| 12 |
| 13 |
| |||
°F °C | 100 | 13 |
| 13 |
| 13 |
| |||
HEAD PRESSURE | 70 | 258 |
| 18.1 | 258 |
| 18.1 | 258 |
| 18.1 |
| 80 | 259 |
| 18.2 | 259 |
| 18.2 | 259 |
| 18.2 |
| 90 | 260 |
| 18.3 | 260 |
| 18.3 | 260 |
| 18.3 |
PSIG kg/cm²G | 100 | 257 |
| 18.1 | 257 |
| 18.1 | 257 |
| 18.1 |
SUCTION PRESSURE | 70 | 32 |
| 2.3 | 32 |
| 2.3 | 32 |
| 2.3 |
| 80 | 33 |
| 2.3 | 33 |
| 2.3 | 33 |
| 2.3 |
| 90 | 33 |
| 2.3 | 33 |
| 2.3 | 33 |
| 2.3 |
PSIG kg/cm²G | 100 | 35 |
| 2.4 | 35 |
| 2.4 | 35 |
| 2.4 |
WATER FLOW FOR CONDENSER | 20gal/h (AT 90°F /WT 70°F) |
PRESSURE DROP OF COOLING WATER LINE | Less than 7 PSIG |
HEAT OF REJECTION FROM CONDENSER | 8,100 BTU/h (AT 90°F /WT 70°F) |
HEAT OF REJECTION FROM COMPRESSOR | 1,300 BTU/h (AT 90°F /WT 70°F) |
HEAT OF REJECTION FROM GEAR MOTOR | 700 BTU/h (AT 90°F /WT 70°F) |
Note:
1.The data not in bold should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
59