Hoshizaki dcm-75ibah LED Lights and Audible Alarm Safeties, Icemaking Sequence Sequence Step

Page 35

B. LED Lights and Audible Alarm Safeties

The "POWER" LED indicates proper control voltage and will remain on unless a control voltage problem occurs. For further details, see "II. Sequence of Operation and Service Diagnosis."

Icemaking Sequence

Sequence Step

LED

Energized

 

 

 

 

 

Components

 

Min.

Max.

 

 

 

 

 

Fill Cycle

 

WTRIN

WV

 

-

 

On until UFS closes. Alarm sounds

 

 

 

 

 

 

 

 

after 90 sec.

 

Ice Purge Cycle

GM

GM, FM

 

5 min.

 

5 min.

 

Freeze Cycle

 

GM, WTRIN* (refill),

GM, Comp,

 

-

 

*On until UFS closes. Alarm

(with refill)

 

COMP

FM, WV*

 

 

 

sounds after 90 sec.

 

 

 

 

(refill)

 

 

 

 

 

Drain Cycle

 

FLUSH (Drain)

DV

 

2 sec.

 

10 min.

 

 

 

 

 

Dispensing Sequence

 

 

Sequence Step

LED

Energized

 

Time LEDs are on

**Dispense Mode Switch

Components

 

Continuous

Portion

Ice Dispense

 

ICE, AM*

IDS**, IDM**,

*AM energizes

60 sec. per

Adjustable

Activation

 

 

AM*

 

.6 sec. every 12

activation

between 0.2 sec.

 

 

 

 

 

 

sec. of cumulative

 

and 20 sec.

 

 

 

 

 

 

dispense time

 

 

Dispense Water

WTRDP

DispWV

 

 

 

 

 

Valve Activation

 

 

 

 

 

 

 

 

The built-in

alarm safeties shut down the appliance.

 

 

No. of Beeps

 

 

Type of Alarm

 

 

Reset Options

(every 5 sec.)

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Low Water Safety

 

 

 

Automatic reset once water supply is restored

 

 

UFS open > 90 seconds after WV energized.

and UFS closes.

 

2

 

Control Switch

 

 

 

Automatic reset once the control switch is

 

 

In "DRAIN" position longer than 15 minutes.

moved to the "ICE" position.

 

3

 

High-Pressure Switch

 

 

 

Automatic reset once pressure drops

 

 

First and second activation in 1 hour.

 

below the high pressure threshold and the

 

 

 

 

 

 

 

highpressure switch closes.

 

4

 

High-Pressure Switch

 

 

 

Call for service. To avoid possible catastrophic

 

 

Third activation in 1 hour.

 

failure, it is recommended to leave the

 

 

 

 

 

 

 

appliance off until this alarm is resolved.

 

 

 

 

 

 

 

Manual reset. Turn power off and on again.

5

 

Freeze Timer

 

 

 

Manual reset. Turn power off and on again.

 

 

WV off > 30 minutes since last WV activation.

 

 

 

6

 

Low Voltage

 

 

 

"POWER OK" LED turns off if voltage

 

 

(92Vac ±5% or less)

 

 

 

protection operates.

 

7

 

High Voltage

 

 

 

The control voltage safeties automatically

 

 

(147Vac ±5% or more)

 

reset when voltage is corrected.

8

 

Gear Motor

 

 

 

Manual reset. Turn power off and on again.

 

 

GMPR contacts fail to close.

 

 

 

 

9

 

Infrared Sensor (S1 dip switch 7)

 

Manual reset. Turn power off and on again.

 

 

(Not used on this model)

 

 

 

 

Legend: AM–agitating motors, Comp–compressor; DispWV–dispense water valve; DV–drain valve; EH–evaporator heater; FM–fan motor; GM–gear motor; GMPR–gear motor protect relay; IDM–ice dispensing motor; IDS–ice dispensing shutter solenoid; UFS–upper float switch; WV–inlet water valve

35

Image 35
Contents DCM-751BAH-OS DCM-751BWH-OS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page DCM-751BAH-OS Construction and Water/Refrigeration Circuit DiagramsDCM-751BWH-OS Ice Making Unit Water/Refrigeration Circuit Diagrams Spout Inlet Water Valve Water Supply Float Diagnosis Control Board Sequence Flow Chart DCM-751BH-OSChart OperationIce Production Check Service DiagnosisDiagnostic Procedure Page Page Page Page Control Board Check 5VDC CB K9 Connector Component Pin # Wire Color 5VDC CB K9 Connector See FigHigh-Pressure Switch HPS Bin Control BC 5VDC CB K8 Connector See Fig5VDC CB K8 Connector Component Pin # Wire Color Gear Motor Protect Relay Gmpr5VDC 0VDC Portion Signal #5 R Red K4 pin closest 5VDC Power Supply #3 W/BK Connector Pin # Wire Color Neutral LBU Open Closed 24VAC CB K2 ConnectorBin Control Check Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Page No Ice Production Possible Cause Startup Diagnostic TablesNo Ice Production Shutdown No Ice Production Possible CauseWater Dispense-Push Button Ice/Water DispensingIce Dispense-Push Button Ice Dispense-Opti-ServeIII. Controls and Adjustments DCM-751BH Control Board LayoutDCM-751BH-OS K2 Connector Drain Valve #10 W/BUEnergized Components Min Max LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Reset Options Every 5 sec Icemaking Sequence Sequence StepDrain Frequency Control S1 dip switch Settings and AdjustmentsDefault Dip Switch Settings Infrared Sensor Shutdown Delay S1 dip switch 1, 2Factory Use S1 Dip Switch 9 Continuous Dispensing Timer S1 dip switch 5Bin Control Selector S1 dip switch Bin Control Shutdown Delay S1 dip switchDrain Power Switch, Control Switch, and Dispense Mode SwitchICE OFFPortion Dispense Mode SwitchContinuous Service for Refrigerant Lines IV. Removal and Replacement of ComponentsEvacuation and Recharge R-404A Refrigerant RecoveryBrazing Evaporator Assembly Components. See Fig Important Notes for Component ReplacementEvaporator Assembly Upper Bearing Wear Check Icemaking UnitRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator 5b. Lower Housing Removal and Replacement of Gear Motor Dispense and Agitating Motors Dispense ComponentsDispense Auger and Agitator Frequency Area Task MaintenanceMaintenance Schedule VI. Preparing the Appliance for Periods of Non-Use Page VII. Disposal DCM-751BAH VIII. Technical Information Specification SheetsDesign without prior Potable Water WATER-COOLED Condenser DCM-751BWH779 758 Reference without *marks 738 719 ICE Production Performance Data800 363 Wiring Diagrams DCM-751BH-OS