No Ice Production - Possible Cause
| Freeze Cycle | |
|
| |
1. Control Board | a) Defective. | |
|
| |
2. Start Relay | a) Defective. | |
3. Start Capacitor or Run Capacitor | a) Defective. | |
|
| |
4. Compressor | a) External protector. | |
|
| |
| b) Motor winding. | |
|
| |
| c) Mechanical failure. | |
5. | a) Dirty condenser. | |
| b) Ambient temperature too warm. | |
|
| |
| c) Fan motor not operating. | |
|
| |
| d) Refrigerant overcharged. | |
|
| |
| e) Defective. | |
| f) Refrigerant lines or components restricted. | |
|
| |
6. Fan Motor | a) Capacitor defective. | |
|
| |
| b) Motor winding. | |
|
| |
| c) Bearing worn out or locked rotor. | |
7. Evaporator | a) Dirty. | |
|
| |
| b) Damaged or defective. | |
|
| |
8. Thermostatic Expansion Valve | a) Bulb loose. | |
(TXV) |
| |
b) Operating erratically. | ||
| ||
9. Refrigerant Charge | a) Low. | |
|
| |
10. Drain Valve | a) Dirty, leaking by. | |
|
| |
| b) Defective coil. | |
|
| |
| c) Defective control board. | |
11. Water System | a) Water leaks. | |
|
| |
| Refill | |
|
| |
1. Water Supply | a) Off. | |
|
| |
2. Control Board | a) No power to float switch or not reading float switch condition. | |
| b) No power to inlet water valve. | |
|
| |
3. Float Switch | a) Float does not move freely. | |
|
| |
| b) Defective. | |
|
| |
4. Inlet Water Valve | a) Clogged or defective. | |
|
| |
| Shutdown | |
1. Bin Control | a) Actuator paddle sticking open. | |
|
| |
| b) Proximity switch defective. | |
|
| |
2. Control Board | a) Defective. | |
|
|