Hoshizaki dcm-75ibah 24VAC CB K2 Connector, Connector Pin # Wire Color Neutral LBU Open Closed

Page 25

3) Fill Cycle–"WTRIN" LED is on: "WTRIN" LED turns on only when the reservoir water level is low enough to open LFS. Diagnosis: Confirm LFS is open. If "WTRIN" LED is off and LFS is open and the control switch is in the "ICE" position (open), replace CB. If "WTRIN" LED is on and water is not filling the reservoir, check for 24VAC at CB K2 connector between pin #8 (W/BR) and a neutral (LBU). If the "WTRIN" LED is on and 24VAC is not present between CB K2 connector pin # 8 (W/BR) and neutral (LBU), confirm 24VAC at CB K2 connector between pin #7 (W/R) and a neutral (LBU). If 24VAC is present between CB K2 connector pin #7 (W/R) and a neutral (LBU) and not between CB K2 connector pin #8 (W/BR) and a neutral (LBU), replace CB.

24VAC CB K2 Connector

 

 

 

 

 

LFS

LFS

Connector

Pin # (Wire Color)

To

Neutral (LBU)

Open

Closed

K2

(CB input power)

Pin #7 (W/R)

 

K8 pin #2 (LBU)

24VAC

24VAC

K2

(WV power)

Pin #8 (W/BR)

To

0VAC

24VAC

 

4) Ice Purge Cycle–"GM" LED is on: "GM" LED turns on once UFS closes (reservoir full). If UFS is closed and "GM" LED is off, replace CB. If "GM" LED is on but GM does not start, check for 115VAC from CB K1 connector pin #3 (DBU) to a neutral (W).

If 115VAC is not present, confirm 115VAC from CB K1 connector pin #2 (BR) to a neutral (W). If 115VAC is present on CB K1 connector pin #2 (BR) but not on CB K1 connector pin #3 (DBU), replace CB.

5) Freeze Cycle–"GM" and "COMP" LED are on: 5-minute ice purge timer terminates or press the "SERVICE" button on CB after the "GM" LED turns on to bypass ice purge cycle. WARNING! Risk of electric shock. Care should be taken not to touch live terminals. After 5-minute ice purge timer terminates, "COMP" LED turns on. If not, replace CB. If "COMP" LED turns on and Comp does not start, check for 115VAC from the CB X1 relay (BR) and (R) to a neutral (W). If 115VAC is present on CB X1 relay (BR) and not on CB X1 relay (R), replace CB.

Legend: AM–agitating motor; BC–bin control; CB–control board; Comp–compressor; CT–control transformer; DCT–drain cycle timer (1-hr.); DV–drain valve; DVT–drain valve timer (2-sec.); FM–fan motor; FT–fill timer (90sec. low water safety); GM–gear motor; GMPR–gear motor protect relay; IPT–ice purge timer; LFS–lower float switch; UFS–upper float switch; WV–inlet water valve

25

Image 25
Contents DCM-751BAH-OS DCM-751BWH-OS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page DCM-751BAH-OS Construction and Water/Refrigeration Circuit DiagramsDCM-751BWH-OS Ice Making Unit Water/Refrigeration Circuit Diagrams Spout Inlet Water Valve Water Supply Float Chart Control Board Sequence Flow Chart DCM-751BH-OSOperation DiagnosisDiagnostic Procedure Service DiagnosisIce Production Check Page Page Page Page Control Board Check High-Pressure Switch HPS 5VDC CB K9 Connector See Fig5VDC CB K9 Connector Component Pin # Wire Color 5VDC CB K8 Connector Component Pin # Wire Color 5VDC CB K8 Connector See FigGear Motor Protect Relay Gmpr Bin Control BC5VDC 0VDC Portion Signal #5 R Red K4 pin closest 5VDC Power Supply #3 W/BK Connector Pin # Wire Color Neutral LBU Open Closed 24VAC CB K2 ConnectorBin Control Check Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Page No Ice Production Diagnostic TablesNo Ice Production Possible Cause Startup Shutdown No Ice Production Possible CauseIce Dispense-Push Button Ice/Water DispensingIce Dispense-Opti-Serve Water Dispense-Push ButtonIII. Controls and Adjustments DCM-751BH Control Board LayoutDCM-751BH-OS K2 Connector Drain Valve #10 W/BUNo. of Beeps Type of Alarm Reset Options Every 5 sec LED Lights and Audible Alarm SafetiesIcemaking Sequence Sequence Step Energized Components Min MaxDefault Dip Switch Settings Settings and AdjustmentsInfrared Sensor Shutdown Delay S1 dip switch 1, 2 Drain Frequency Control S1 dip switchBin Control Selector S1 dip switch Continuous Dispensing Timer S1 dip switch 5Bin Control Shutdown Delay S1 dip switch Factory Use S1 Dip Switch 9ICE Power Switch, Control Switch, and Dispense Mode SwitchOFF DrainContinuous Dispense Mode SwitchPortion Service for Refrigerant Lines IV. Removal and Replacement of ComponentsBrazing Refrigerant RecoveryEvacuation and Recharge R-404A Evaporator Assembly Components. See Fig Important Notes for Component ReplacementEvaporator Assembly Upper Bearing Wear Check Icemaking UnitRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator 5b. Lower Housing Removal and Replacement of Gear Motor Dispense Auger and Agitator Dispense ComponentsDispense and Agitating Motors Maintenance Schedule MaintenanceFrequency Area Task VI. Preparing the Appliance for Periods of Non-Use Page VII. Disposal DCM-751BAH VIII. Technical Information Specification SheetsDesign without prior Potable Water WATER-COOLED Condenser DCM-751BWH779 758 Reference without *marks 738 719 ICE Production Performance Data800 363 Wiring Diagrams DCM-751BH-OS