Hoshizaki dcm-75ibah service manual III. Controls and Adjustments

Page 32

III. Controls and Adjustments

A Hoshizaki exclusive control board is employed in the DCM-751 series.

All models are pretested and factory set.

For a control board check procedure, see "II.C. Control Board Check."

NOTICE

Fragile, handle very carefully.

The control board contains integrated circuits, which are susceptible to failure due to static discharge. It is especially important to touch the metal part of the appliance when handling or replacing the control board.

Do not touch the electronic devices on the control board or the back of the control board.

Do not change wiring and connections. Do not misconnect terminals.

Do not short out power supply to test for voltage.

Always replace the whole control board assembly if it goes bad.

32

Image 32
Contents DCM-751BAH-OS DCM-751BWH-OS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page Construction and Water/Refrigeration Circuit Diagrams DCM-751BAH-OSDCM-751BWH-OS Ice Making Unit Water/Refrigeration Circuit Diagrams Spout Inlet Water Valve Water Supply Float Control Board Sequence Flow Chart DCM-751BH-OS ChartOperation DiagnosisIce Production Check Service DiagnosisDiagnostic Procedure Page Page Page Page Control Board Check 5VDC CB K9 Connector Component Pin # Wire Color 5VDC CB K9 Connector See FigHigh-Pressure Switch HPS 5VDC CB K8 Connector See Fig 5VDC CB K8 Connector Component Pin # Wire ColorGear Motor Protect Relay Gmpr Bin Control BC5VDC 0VDC Portion Signal #5 R Red K4 pin closest 5VDC Power Supply #3 W/BK 24VAC CB K2 Connector Connector Pin # Wire Color Neutral LBU Open ClosedBin Control Check Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Page No Ice Production Possible Cause Startup Diagnostic TablesNo Ice Production No Ice Production Possible Cause ShutdownIce/Water Dispensing Ice Dispense-Push ButtonIce Dispense-Opti-Serve Water Dispense-Push ButtonIII. Controls and Adjustments Control Board Layout DCM-751BHK2 Connector Drain Valve #10 W/BU DCM-751BH-OSLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Reset Options Every 5 secIcemaking Sequence Sequence Step Energized Components Min MaxSettings and Adjustments Default Dip Switch SettingsInfrared Sensor Shutdown Delay S1 dip switch 1, 2 Drain Frequency Control S1 dip switchContinuous Dispensing Timer S1 dip switch 5 Bin Control Selector S1 dip switchBin Control Shutdown Delay S1 dip switch Factory Use S1 Dip Switch 9Power Switch, Control Switch, and Dispense Mode Switch ICEOFF DrainPortion Dispense Mode SwitchContinuous IV. Removal and Replacement of Components Service for Refrigerant LinesEvacuation and Recharge R-404A Refrigerant RecoveryBrazing Important Notes for Component Replacement Evaporator Assembly Components. See FigEvaporator Assembly Icemaking Unit Upper Bearing Wear CheckRemoval and Replacement of Extruding Head Removal and Replacement of AugerRemoval and Replacement of Evaporator 5b. Lower Housing Removal and Replacement of Gear Motor Dispense and Agitating Motors Dispense ComponentsDispense Auger and Agitator Frequency Area Task MaintenanceMaintenance Schedule VI. Preparing the Appliance for Periods of Non-Use Page VII. Disposal VIII. Technical Information Specification Sheets DCM-751BAHDesign without prior DCM-751BWH Potable Water WATER-COOLED Condenser779 758 Reference without *marks 738 719 Performance Data ICE Production800 363 Wiring Diagrams DCM-751BH-OS