Hoshizaki dcm-75ibah service manual Ice Making Unit

Page 9

3. Ice Making Unit

Extruding Head

Cubelet Cutter

 

and Upper Bearing

 

Allen Head Cap Screw

 

Washer

 

 

Extruding Head Heater

Auger

 

Cylinder

 

Evaporator

 

Insulation

 

Mechanical Seal

Allen Head Cap Screw

O-Ring

with Washer

 

Housing and

 

Lower Bearing

 

Hex Head Bolt

 

with Washer

Gear Motor

 

 

9

Image 9
Contents DCM-751BAH-OS DCM-751BWH-OS Hoshizaki AMERICA, INC Contents Page Important Safety Information Page DCM-751BAH-OS Construction and Water/Refrigeration Circuit DiagramsDCM-751BWH-OS Ice Making Unit Water/Refrigeration Circuit Diagrams Spout Inlet Water Valve Water Supply Float Chart Control Board Sequence Flow Chart DCM-751BH-OSOperation DiagnosisService Diagnosis Diagnostic ProcedureIce Production Check Page Page Page Page Control Board Check 5VDC CB K9 Connector See Fig High-Pressure Switch HPS5VDC CB K9 Connector Component Pin # Wire Color 5VDC CB K8 Connector Component Pin # Wire Color 5VDC CB K8 Connector See FigGear Motor Protect Relay Gmpr Bin Control BC5VDC 0VDC Portion Signal #5 R Red K4 pin closest 5VDC Power Supply #3 W/BK Connector Pin # Wire Color Neutral LBU Open Closed 24VAC CB K2 ConnectorBin Control Check Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Page Diagnostic Tables No Ice ProductionNo Ice Production Possible Cause Startup Shutdown No Ice Production Possible CauseIce Dispense-Push Button Ice/Water DispensingIce Dispense-Opti-Serve Water Dispense-Push ButtonIII. Controls and Adjustments DCM-751BH Control Board LayoutDCM-751BH-OS K2 Connector Drain Valve #10 W/BUNo. of Beeps Type of Alarm Reset Options Every 5 sec LED Lights and Audible Alarm SafetiesIcemaking Sequence Sequence Step Energized Components Min MaxDefault Dip Switch Settings Settings and AdjustmentsInfrared Sensor Shutdown Delay S1 dip switch 1, 2 Drain Frequency Control S1 dip switchBin Control Selector S1 dip switch Continuous Dispensing Timer S1 dip switch 5Bin Control Shutdown Delay S1 dip switch Factory Use S1 Dip Switch 9ICE Power Switch, Control Switch, and Dispense Mode SwitchOFF DrainDispense Mode Switch ContinuousPortion Service for Refrigerant Lines IV. Removal and Replacement of ComponentsRefrigerant Recovery BrazingEvacuation and Recharge R-404A Evaporator Assembly Components. See Fig Important Notes for Component ReplacementEvaporator Assembly Upper Bearing Wear Check Icemaking UnitRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator 5b. Lower Housing Removal and Replacement of Gear Motor Dispense Components Dispense Auger and AgitatorDispense and Agitating Motors Maintenance Maintenance ScheduleFrequency Area Task VI. Preparing the Appliance for Periods of Non-Use Page VII. Disposal DCM-751BAH VIII. Technical Information Specification SheetsDesign without prior Potable Water WATER-COOLED Condenser DCM-751BWH779 758 Reference without *marks 738 719 ICE Production Performance Data800 363 Wiring Diagrams DCM-751BH-OS