g.
Opti‑Serve sensor, check for the correct VDC from the locations given in the "Disengaged" column in the table below. If the VDC is different than in the table, replace CB. If the VDC is correct, engage the Opti‑Serve sensor. "WTRDP" LED turns on. If not, confirm that the water dispense signal VDC matches the "Engaged" column in the table below. If not, replace the
5VDC CB K7 Connector
Component | Pin # (Wire Color) | To | CB VDC Ground | Disengaged | Engaged | |
VDC Sensor Ground | #7 (R) |
| Red K4 pin closest | 0VDC | 0VDC | |
Water Dispense Signal | #8 (W) | To | 0VDC | 5VDC | ||
to black K3 | ||||||
5VDC Power Supply | #9 (BK) |
| 5VDC | 5VDC | ||
|
|
Red positive test lead to red K4 connector pin closest
to black K3
Red Positive Test Lead
Multimeter |
5VDC |
Black Negative |
|
Test Lead | Control Board K7 Connector |
connector
Water Dispense (BK) |
|
(5VDC power) |
|
Water Dispense (W) | Water Dispense (R) |
(switch signal) | (VDC GND) |
Fig. 4
22