Page 35

If the cavity temperature is above 212°F, automatic Cool Down will occur. During automatic Cool Down, the Time Display will show the rain symbol instead of time.

The timer will start counting down.

The steam generator will fill with water until the water level controls shut off the fill.

The steam generator heater elements will produce steam for 30 minutes. After 30 minutes, the steam generator tank will drain.

The Time Display will show 10 minutes. The timer will not count down.

The Steam Generator will fill and drain two times. The fill time is programmed for each model.

The Time Display will begin counting down, the Steam Generator heaters are ON with steam being generated.

At the end of the ten minute interval, the Steam Generator tank will drain.

'DONE' will display in the Temperature Display indicating that the Clean Cycle is complete.

NOTE: If an error occurs during the Clean Cycle, 'FAIL' will display in the Temperature Display instead of 'DONE'.

Per the instructions in the filter cartridge replacement and preventive maintenance kit: Retest the water, return the response card and replace the filter cartridge.

– 35 –

Image 35
Contents Installation Table of Contents Stacking Kits UnpackingLocation Condensate Drip PAN Available Installation AccessoriesLegs or Casters LevelingWater Supply Connections Fig Plumbing ConnectionsWater Requirements Water RequirementsBefore First USE Electrical ConnectionElectrical Data Vent HoodGrease Filter Door Opening and ClosingLoading the Oven Cool Down Unloading the OvenBuzzer Programmable Controls MinProgram Number Cooking ModeOFF DownCooking with the Probe Using the Temperature ProbeProbe Entering a Cooking Program Temperature Probe ApplicationsProduct Programming Memory Recalling a Program from Memory 0 F Fish Convection Baking Applications HOT AIR Mode2F 1 Vegetables Steaming Applications5 F Beef Combi ApplicationsCook and Hold 300 F Cook and Hold ApplicationsSave PhaseExample Program Menu Card Mode Finish Oven ControlTime Temp Humidifier Deluxe Manual Control Selector Switch OFFEntering a Manual Cooking Operation Deluxe Control Cooking Time Standard Manual ControlEntering a Manual Cooking Operation Standard Control Complete Cleaning CleaningDaily Cleaning Drain Grating Clean Cycle Deliming Tank Volume and Chemical Requirements Clean Cycle Deliming ProcedurePage Configuration Mode Programmable Control Elevation FAN Motor Coefficients TableConfiguration Mode Manual Control Standard or Deluxe Number Minimum Value Maximum Value Service and Parts Information Service Adjustments