Performance Data Sheet
Hotpoint
Filtration by GE SmartWaterTM
HXRT Cartridge
Performance Tested to NSF/ANSI*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter | USEPA | Influent | Effluent | % Reduction | |||
| MCL | Challenge |
| Average | Maximum | Average | Minimum |
Chlorine | — | 1.96 ppm | 0.30 ppm | 0.44 ppm | 85 | 78 | |
T & O | — | — | — | — | — | — | |
Particulate** | — | 2296 |
| 62 | 116 | 97.3 | 94.9 |
*Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C
**Measurement in Particles/ml of 10µ Particles
Operating Specifications
■Capacity: certified for up to 250 gallons (946 L)
■Pressure requirement:
■Temperature:
■Flow rate: 0.5 gpm (1.9 Lpm)
General Installation/Operation/Maintenance Requirements
■Flush new cartridge at full flow for 60 seconds to purge out trapped air.
■Replace cartridge when flow becomes too slow; at least every six months.
Special Notices
■Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
■This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
■Check for compliance with the state and local laws and regulations.
General Electric, Appliance Park, Louisville, KY 40225 | © 1997 GE |
23