Drain Requirements

A new drain hose is supplied with your dishwasher.

If this is not long enough, use a new drain hose with a maximum length of 12’ (3.7 m) (Part Number 3385556) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the 1” (2.5 cm) drain connector of the dishwasher.

Make sure to connect drain hose to waste tee or disposer inlet above drain trap in house plumbing and 20” (50.8 cm) minimum above the floor. It is recommended that the drain hose either be looped up and securely fastened to the underside of the counter, or be connected to an air gap.

Make sure to use an air gap if the drain hose is connected to house plumbing lower than 20” (50.8 cm) above subfloor or floor.

Use of air gap

Air gap

Use ¹⁄₂” minimum I.D. drain line fittings.

If required the air gap should be installed in accordance with the air gap installation instructions, when connecting the air gap a rubber hose (not provided) will be needed to connect to the waste tee or disposer inlet.

Water Supply Requirements

A hot water line with 20 to 120 psi (138 to 862 kPa) water pressure can be verified by a licensed plumber.

120°F (49°C) water at dishwasher.

³⁄₈” O.D. copper tubing with compression fitting or

flexible braided water supply line (Part Number 4396897RP) NOTE: ¹⁄₂” minimum plastic tubing is not recommended.

A 90° elbow with ³⁄₈” N.P.T. external pipe threads on one end.

Do not solder within 6” (15.2 cm) from water inlet valve.

Electrical Requirements

Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition and all local codes and ordinances.

A copy of the above code standards can be obtained from: National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169

You must have:

120-volt, 60 Hz, AC-only, 15- or 20- amp., fused electrical supply.

copper wire only.

We recommend:

a time-delay fuse or circuit breaker.

a separate circuit.

If connecting dishwasher with a power supply cord:

• Use UL Listed power

supply cord kit (Part Number 4317824)

marked for use with dishwasher.

Power supply cord must plug into

a grounded 3 prong outlet, located in the cabinet next to the dishwasher opening. Outlet must meet all local codes and ordinances.

If connecting dishwasher with direct wiring:

Use flexible, armored or nonmetallic sheathed,

copper wire with grounding wire that meets

the wiring requirements for your home and local codes and ordinances.

• Use a UL Listed/CSA Approved strain relief.

5

Image 5
Contents Table of Contents Table des matières W10261420A Dishwasher Safety Location Requirements Tools and PartsPliers Flat-blade Screwdriver Flashlight Bath towel Shallow pan Wood blockMinimum, measured from narrowest point of opening Product and Cabinet Opening DimensionsWater Supply Requirements Drain RequirementsElectrical Requirements Use of air gapPrepare Cabinet Opening New Utilities Prepare Cabinet Opening Existing UtilitiesPrepare and Route Water Line Install Drain Hose Waste disposer with air gap No waste disposer no air gapNo waste disposer with air gap Prepare Dishwasher Install strain relief Make Power Supply Cord ConnectionPower Cord-Route cord into terminal box Power Supply Cord- Connect ground wireDetermine Cabinet Opening Move Dishwasher into Cabinet Opening Open and close door Check for plumb and adjust legs if neededCloses too quickly- Decrease spring tension Door falls open- Increase spring tensionConnect to Water Supply Slide clamp onto connector Make Direct Wire Electrical ConnectionDirect Wire--Route cable into terminal box Connect to DrainDirect Wire-Connect remaining wires Direct Wire-Connect ground wireDirect Wire-Secure cable in conduit connector Direct Wire-Reinstall terminal box coverSecure Dishwasher in Cabinet Opening Reinstall access panels Complete InstallationRemove towel and replace lower dishwasher rack Check lower panel edgeReconnect power Power supply cord-Plug into a grounded 3 prong outletCheck Operation If Dishwasher Does Not OperatePréparation de la cavité dencastrement Instructions d’installation suiteOutillage et pièces Exigences d’emplacementMinimum à l’endroit le plus étroit de la cavité 24 cm Dimensions Produit et cavité d’encastrementEn gris sur les parois de la cavité d’encastrement Spécifications de l’alimentation En eau Spécifications de l’évacuationSpécifications électriques Utilisation d’un brise-videFermer l’arrivée d’eau Déconnecter la source de courant électriqueMoyens de raccordement aux divers circuits déjà existants? Quel type de raccordement électrique sera utilisé?Préparation et raccordement à la Canalisation deau Installation du tuyau ’évacuation Pas de broyeur à déchets avec brise-vide Pas de broyeur à déchets pas de brise-videBroyeur à déchets avec brise-vide Dépose des panneaux Préparation du lave-vaisselleAttachez l’isolation Raccordement électrique Cordon d’alimentation Installation du serre-câbleÔter le couvercle du boîtier De connexion électrique Cordon d’alimentation Conducteur de liaison à la terreConfiguration de câblage Dimensions de la cavité ’encastrementMesure des dimensions Tableau de réglage Hauteur du lave-vaisselleDe l’ouverture de la cavité Roues et pieds RéglagePlancher surélevé addition de cales selon le besoin Redresser le lave-vaisselleInsertion du lave-vaisselle dans la cavité d’encastrement La tension des ressortsContrôle de l’aplomb et réglage des pieds si nécessaire IsolantInspection/Recherche des fuites Raccordement à la canalisation Dalimentation en eauRaccordement électrique Câblage direct Raccordement à l’égoutMise en place de la bride Bride de tuyau position finaleCâblage direct Immobilisation par le connecteur de conduit Câblage direct Raccordement des autres conducteursUtilisation d’une serviette Extraction du panier inférieurArrimer le lave-vaisselle Liberté de manœuvre de la porteRéinstallation du panier inférieur retrait de la serviette Achever l’installationRéinstallation des panneaux daccès Contrôle du panneau de plintheSi le lave-vaisselle ne Fonctionne pas Contrôle du fonctionnementConseils additionnels Reconnecter la source de courant électriqueW10261420A