WhisperKool 5000 owner manual Introduction

Page 10

INTRODUCTION

Customer Service

Thank you for purchasing a WhisperKOOL Extreme Series cooling unit. We strive to provide the highest quality prod- ucts and the best possible customer service. If you have any questions about your WhisperKOOL unit, please call us at 1(800) 343-9463.

Using the Manual

This User’s Manual is intended to assist in the proper installation and maintenance of the WhisperKOOL Extreme cool- ing system. In order to ensure the longevity of your cooling unit, the equipment should be installed properly and have a proper care and maintenance schedule. Please read and review this manual carefully and keep it for future reference.

What Is the WhisperKOOL Extreme Series Cooling System?

The WhisperKOOL Extreme Series system is a specialized refrigeration unit designed for one purpose only: to main- tain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines. It is a self-contained cooling unit designed to be used as a forced-air through-the-wall unit or as a remote mount unit with external ductwork connections.

How Does the WhisperKOOL Extreme Series Work?

The WhisperKOOL Extreme Series cooling system is especially designed for the use and application to maintain optimal conditions for wine storage and aging. The system is fully self-contained and can be installed as a “Through- The-Wall’ application, or the unit is capable of an even more flexible “Ducted” application, which allows the unit to be placed in an indoor remote site, resulting in a quiet airflow. The standard “Through-the-Wall” and ducted units are temperature controlled via a bottle probe, and the ducted system comes standard with a remote key board that can be located up to 50 ft from the cooling system (Note: Remote Unit comes standard with a 50 ft bottle probe and 50 ft. of cable for the remote keypad, additional lengths are optional).

Temperature Setting

The WhisperKOOL Extreme unit can be set at any temperature within the acceptable wine-aging range of 50°F to 67°F. It is designed to cool up to 55°F cooler than the ambient temperature of the space to which it is exhausting.

Page 8

EXti 110111

Image 10
Contents Extreme 5000 Page Table of Contents Quick Reference Guide Front / Side ViewFully Ducted Front / Side View 8000 / 8000 Rear / Side View Compressor Access Panel Standard Controller Layout Model Unit SpecificationsFAN Speed Reference Low Med HighIntroduction Receiving & Inspecting the Unit Review the Packing Slip to Verify ContentsCheck the Box for the following contents 5000 Receiving and Inspecting the UnitQuick Start Guide Insulation Preparing the Wine CellarVapor Barrier Unobstructed Airflow Mounting the UnitDoor and Door Seal Ventilation Air Intake Cellar Wall Ambient Temperature FactorUsing any other ducting system will void the warranty Exhaust FanElectrical Needs PRE-INSTALLATIONElectrical Inlets Preparing the Installation Location Minimum Tools NeededSingle Piece Mounting Bracket Preparing the System for InstallationMounting Bracket Installation Applying Insulation Tape8000 Mounting FlangesFlush Installation Exterior Grille InstallationNon-Flush Installation Optional Exterior Grille8000 Installing the System THROUGH-THE-WALL InstallationBack of Unit General Duct Recommendations Ducting OverviewUse of Ductwork Location of Supply and Return GrillesThree-Quarter Duct Configuration Wine Cellar Ducting ConfigurationsHalf Duct Configuration Wine Cellar Adjacent RoomFully Ducted Attic Mounted SystemInstalling the Duct Plenums Remote Controller Installation Mounting Bracket Condensation Drain Line Tube Failure to install the drain line voids the warrantyDrain Line Drain LineLiquid Measuring Thermostat System Liquid Measuring Thermostat SystemSelf-Calibrating Probe To Use the thermostat59/59 60/61 Multi FAN Speed Control57/57 System Operation Up and Down Button/Symbol Normal FunctionsStandard Controller Functions ArrowsAlarm Anti-FrostPage Standard Remote Controller Functions Button Normal FunctionsCheck Evaporator Probe connection at green terminal block on Cpsm Mode Remote Wire Schematic Maintenance Schedule Unit does not run/power up Possible Cause Solution Cellar Temperature is to Warm Possible Cause SolutionPossible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Compressor short cycles Possible Cause SolutionTechnical Assistance Accessories for Cooling UnitsContact WhisperKOOL Customer Service Condensate Pump KitInstallation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Model Serial NumberA Installed by Date Sales and USE TAXPage Page WhisperKOOL