WhisperKool 5000 Optional Exterior Grille, Exterior Grille Installation, Non-Flush Installation

Page 20

OPTIONAL EXTERIOR GRILLE

5000 / 5000

Exterior Grille Installation

The exterior grille is required on all installations where the exhaust side of the unit is exposed to the outside of the dwelling (i.e. rain and weather).

Non-Flush Installation

Install the system according to the standard through-the-wall procedure. After the system is installed, place the exte- rior grille over the exhaust side filer grille and line up the screw holes on the top, bottom, and sides. Use the supplied

(8) self tapping screws to fasten the grille to the unit.

Flush Installation

This installation is slightly different because you are utilizing the same holes for both the mounting bracket and exte- rior grille.

1.Slide the mounting bracket onto the unit followed by the exterior grille, bring the two pieces together by slid- ing the exterior grille over the mounting bracket side flanges.

2.Align the (2) top screw holes of the exterior grill with the top screw locations on the system, use the supplied self tapping screws to fasten the grille.

3.Repeat step 2 on the bottom of the system.

4.You will notice the side holes do not line up, use the supplied self tapping screws to fasten the grille and bracket to the system ensuring the bracket stays perpendicular/square.

5.Continue through-the-wall installation.

It is required to use self tapping screws provided. Do not drill screws into unit.

Non-Flush Installation

Flush Installation

Page 18

EXti 110111

Image 20
Contents Extreme 5000 Page Table of Contents Quick Reference Guide Front / Side ViewFully Ducted Front / Side View 8000 / 8000 Rear / Side View Compressor Access Panel Standard Controller Layout Unit Specifications FAN Speed ReferenceModel Low Med HighIntroduction Review the Packing Slip to Verify Contents Check the Box for the following contents 5000Receiving & Inspecting the Unit Receiving and Inspecting the UnitQuick Start Guide Vapor Barrier Preparing the Wine CellarInsulation Door and Door Seal Mounting the UnitUnobstructed Airflow Air Intake Cellar Wall Ambient Temperature Factor Using any other ducting system will void the warrantyVentilation Exhaust FanElectrical Inlets PRE-INSTALLATIONElectrical Needs Preparing the Installation Location Minimum Tools NeededPreparing the System for Installation Mounting Bracket InstallationSingle Piece Mounting Bracket Applying Insulation Tape8000 Mounting FlangesExterior Grille Installation Non-Flush InstallationFlush Installation Optional Exterior Grille8000 Back of Unit THROUGH-THE-WALL InstallationInstalling the System Ducting Overview Use of DuctworkGeneral Duct Recommendations Location of Supply and Return GrillesDucting Configurations Half Duct Configuration Wine CellarThree-Quarter Duct Configuration Wine Cellar Adjacent RoomFully Ducted Attic Mounted SystemInstalling the Duct Plenums Remote Controller Installation Mounting Bracket Failure to install the drain line voids the warranty Drain LineCondensation Drain Line Tube Drain LineLiquid Measuring Thermostat System Self-Calibrating ProbeLiquid Measuring Thermostat System To Use the thermostat57/57 Multi FAN Speed Control59/59 60/61 System Operation Button/Symbol Normal Functions Standard Controller FunctionsUp and Down ArrowsAlarm Anti-FrostPage Standard Remote Controller Functions Button Normal FunctionsCheck Evaporator Probe connection at green terminal block on Cpsm Mode Remote Wire Schematic Maintenance Schedule Unit does not run/power up Possible Cause Solution Cellar Temperature is to Warm Possible Cause SolutionUnit leaks water Possible Cause Solution Unit runs but does not cool Possible Cause SolutionPossible Cause Solution Compressor short cycles Possible Cause SolutionAccessories for Cooling Units Contact WhisperKOOL Customer ServiceTechnical Assistance Condensate Pump KitInstallation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Model Serial NumberA Installed by Date Sales and USE TAXPage Page WhisperKOOL